XBee®/XBee‐PRO® ZB SMT RF Modules
ZigBee Explicit Rx Indicator
Frame Type:0x91
When the modem receives a ZigBee RF packet it is sent out the serial port using this message type (when
AO=1).
Frame Fields
Start Delimiter
Length
Offset Example
0 0x7E
Description
MSB 1 0x00
LSB 2 0x18
3 0x91
Number of bytes between the length and the checksum
Frame Type
MSB 4 0x00
5 0x13
6 0xA2
64-bit Source
Address
64-bit address of sender. Set to 0xFFFFFFFFFFFFFFFF
(unknown 64-bit address) if the sender's 64-bit address is
unknown.
7 0x00
8 0x40
9 0x52
10 0x2B
LSB 11 0xAA
MSB 12 0x7D
LSB 13 0x84
16-bit Source
Network Address
A
P
I
16-bit address of sender.
Endpoint of the source that initiated the
transmission
Source Endpoint
14 0xE0
15 0xE0
P
a
c
k
e
t
Endpoint of the destination the message is
addressed to.
Destination Endpoint
Frame-specific Data
16 0x22
17 0x11
18 0xC1
19 0x05
Cluster ID the packet was addressed
to.
Cluster ID
Profile ID
Profile ID the packet was
addressed to.
0x01 – Packet Acknowledged
0x02 – Packet was a broadcast packet
0x20 - Packet encrypted with APS encryption
0x40 - Packet was sent from an end device (if known)
Receive Options
20 0x02
21 0x52
22 0x78
23 0x44
24 0x61
25 0x74
26 0x61
27 0x52
Received Data
Received RF data
Checksum
0xFF - the 8 bit sum of bytes from offset 3 to this byte.
Example: Suppose a device with a 64-bit address of 0x0013A200 40522BAA, and 16-bit address 0x7D84
sends a broadcast data transmission to a remote device with payload "RxData". Suppose the transmission
was sent with source and destination endpoints of 0xE0, cluster ID=0x2211, and profile ID=0xC105. If
AO=1 on the receiving device, it would send the above frame out its serial port.
© 2010 Digi International, Inc.
110