HBR Series of Railway Half-Brick  
Up to 150 Watts DC-DC Converter  
FEATURE CHARACTERISTICS  
PARAMETER  
CONDITIONS  
Model  
Min.  
Typical  
Max.  
Units  
Switching Frequency  
All  
200  
KHz  
On/Off Control, Positive Remote On/Off logic  
Logic Low (Module Off)  
Von/off at Ion/off=1.0mA  
All  
All  
1.8  
75  
V
V
3.5 or  
Open  
Circuit  
Logic High (Module On)  
Von/off at Ion/off=0.0uA  
On/Off Control, Negative Remote On/Off logic  
Logic Low (Module On)  
Logic High (Module Off)  
Von/off at Ion/off=1.0mA  
All  
All  
1.8  
75  
V
V
Von/off at Ion/off=0.0uA  
3.5 or  
Open  
Circuit  
On/Off Current for both remote on/off logic  
Leakage Current for both remote on/off logic  
Off Converter Input Current  
Ion/off at Von/off=0.0V  
All  
All  
All  
All  
All  
All  
0.3  
5
1
mA  
µA  
mA  
%
Logic High, Von/off=15V  
30  
Shutdown input idle current  
Pout=max rated power  
10  
Output Voltage Trim Range  
-10  
115  
+10  
140  
Output Over Voltage Protection  
Over-Temperature Shutdown  
125  
105  
%
°C  
GENERAL SPECIFICATIONS  
PARAMETER  
MTBF  
CONDITIONS  
Model  
Min.  
Typical  
TBD  
Max.  
Units  
K hours  
grams  
Io=100% of Io max; Ta=25°C per MIL-HDBK-217F  
All  
All  
Weight  
95  
Safety  
Meet UL60950-1, LVD  
EMC (see Item 7.2)  
EMI  
Meet EN50121-3-2 (with External Filter) EN50155  
Meet EN55011 Class A  
Meet EN61000-4-2 Air 8000V Perf. Criteria A  
Meet EN61000-4-2 Contact 6KV Perf. Criteria A  
Meet EN61000-4-3 20V/m Perf. Criteria A  
Meet EN61000-4-4 2KV Perf. Criteria A  
Meet EN61000-4-5 1KV Perf. Criteria B  
Meet EN61000-4-6 10Vr.m.s Perf. Criteria A  
Meet EN61373, EN50155  
ESD  
Radiated Immunity  
Fast Transient  
Surge  
Conducted Immunity  
Shock/Vibration  
Humidity  
95% RH max. Non Condensing  
Environmental  
Meet EN60068-2-1, EN60068-2-2, EN60068-2-30, EN50155,  
September 16 -2017 A.04  