ES51932
22,000 Counts Auto DMM
2. Measurement Mode Switching
Measurement mode depends on the logic level of SLACDC, FC1, FC2, FC3, FC4, FC5,
and KEY. When FC5 is high, the measurement mode list is below.
SLACDC FC1
FC2
0
1
1
0
1
1
0
0
0
0
0
1
0
1
1
1
0
1
1
0
1
1
0
0
0
0
0
1
0
1
1
1
FC3
1
0
1
0
1
0
0
1
0
1
0
1
1
1
0
0
1
0
1
0
1
0
0
1
0
1
0
1
1
1
0
0
FC4
1
1
1
0
0
0
0
0
1
1
1
1
0
0
0
1
1
1
1
0
0
0
0
0
1
1
1
1
0
0
0
1
Mode
Function of KEY
DCV ↔ ACV
DCA ↔ ACA
DCA ↔ ACA
DCA ↔ ACA
DCmV ↔ ACmV
DCA ↔ ACA
DCA ↔ ACA
DCA ↔ ACA
DCA ↔ ACA
Ω ↔ Continuity
Continuity ↔ Diode
Ω ↔ Continuity ↔ Diode
—
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
1
1
0
0
0
0
0
0
0
1
1
1
0
1
1
1
1
1
0
0
0
0
0
0
0
Voltage Measurement
Auto DC Current Measurement(µA)
Auto DC Current Measurement(mA)
322A DC Current Measurement(A)
DCmV 220.00mV
2Manual DC 22.000A
Manual DC 220.00A
Manual DC 2200.0A
Manual DC 22000A
Resistance Measurement
Continuity Check
Resistance Measurement
Frequency Measurement
Capacitance Measurement
Temperature Measurement
Resistance Measurement
Voltage Measurement
Auto AC Current Measurement(µA)
Auto AC Current Measurement(mA)
322A AC Current Measurement(A)
ACmV 220.00mV
—
℃ ↔ ℉
Ω ↔ Diode
ACV ↔ DCV
ACµA ↔ DCµA
ACmA ↔ DCmA
ACA ↔ DCA
ACmV ↔ DCmV
ACA ↔ DCA
ACA ↔ DCA
ACA ↔ DCA
ACA ↔ DCA
—
2Manual AC 22.000A
Manual AC 220.00A
Manual AC 2200.0A
Manual AC 22000A
1ADP0(22000)
—
—
—
—
ADP1(2200.0)
ADP2(220.00)
ADP3(22.000)
ADP4(2.2000)
Temperature Measurement
Capacitance Measurement (Clamp)4
℉ ↔ ℃
—
X means “don’t care”.
Note1: When FC5 is high, the ADP0, ADP1, ADP2, ADP3 and ADP4 modes can display minus sign.
Note2: The manual DC/AC 22A, 220A, 2200A and 22000A modes are designed for clampmeter.
Note3: DC 22A and AC 22A current measurement modes, (FC1~4) = (0, 0, 0, 0), are designed for
multimeter.
Note4: It provides the ranges from 2.2uF to 220mF in this mode.
Ver. 1.2
13