DMM Analog front end/Insulation  
2.5 Capacitance Measurement  
MPU send write command to select the capacitance measurement function.  
F3  
F2  
F1  
F0  
Measurement mode  
Read data bytes  
D0(0:18)  
1
0
0
0
Capacitance mode  
Note1: D0 is binary format. ASIGN bit is ignored.  
Range control for capacitance mode  
Measurement Period  
0.5 sec  
Q2  
0
0
0
0
1
1
1
1
Q1  
0
0
1
1
0
0
1
1
Q0  
0
1
0
1
0
1
0
1
Full Scale Range Relative Resistor  
6.0000nF*  
60.000nF*  
600.00nF*  
6.0000uF*  
60.000uF*  
600.00uF*  
6.0000mF*  
60.000mF*  
-
0.5 sec  
1.25 sec  
OVX pin VR  
-
0.4 sec max.  
0.5 sec max.  
1.0 sec max.  
1.35 sec max.  
6.75 sec max.  
R9K / R1K  
R9K / R1K  
R9K / R1K  
R9K / R1K  
R9K / R1K  
The displayed counts in ES51998 capacitance mode is recommended to be divided by  
10. (6000 counts displayed is recommended)  
ALARM bit at capacitance mode is used for increasing the ranging speed. If MPU  
check the ALARM=1 at lower range, it could set the next range to 6.000uF directly  
and the ADC output should be ignored.  
STA0 status bit is used for detection of DUT capacitor voltage. If STA0=1, the internal  
capacitor discharging mode is active and the capacitance measurement is inhibited. It is  
recommended to discharge the DUT capacitor externally.  
2.6 Continuity Check measurement  
MPU send write command to select the continuity measurement function.  
F3  
F2  
F1  
F0  
Measurement mode  
Read data bytes  
D0(0:18), D1(0:9)  
0
1
0
1
Continuity mode  
Note1: D0/D1 both are binary format. ASIGN/BSIGN bits both are ignored.  
Continuity mode shares the same configuration with 600.0resistance measurement  
circuit and support the low-resistance detection. If the STBEEP output (pin64) is low, it  
means the low-resistance status is detected (It means the OVX terminal voltage less than  
-7mV). It could be faster than the FADC result, so MPU could monitor the STBEEP output  
and FADC (D1) data output make the high speed detection for short circuit detection. Set  
SHBP=1 to enable the built-in buzzer driving automatically when STBEEP is active.  