DMM Analog front end/Insulation  
2. Operating Modes  
2.1. Voltage Measurement  
MPU send write command to select the voltage measurement function. The Hz mode  
measurement is available to be enabled with the ACV function (set AC bit to 1)  
simultaneously. The measured signal is applied to VR1 terminal (pin25) through 10M.  
See the next table of function command:  
F3  
0
F2  
0
F1  
0
F0  
0
AC  
0
Measurement mode  
DCV mode  
Read data bytes  
D0(0:18), D1(0:9)  
0
0
0
0
1
ACV mode  
D0(0:18), D1(0:9)  
D0(0:18), D1(0:9), D2(0:18), D3(0:18)  
0
0
0
1
1
ACV + Hz(%) mode  
Note1: D0/D1/D3 all are binary format. ASIGN/BSIGN are the sign bit of D0/D1, respectively.  
Note2: See PEAK mode (section 2.10) also.  
Range control for voltage mode (ACV/DCV)  
Q2 Q1 Q0  
Full Scale Range  
600.00mV  
6.0000V  
Divider Ratio  
1
Resister Connection  
VR1 (10M)  
VR2 (1.111M)  
VR3 (101k)  
VR4 (10.01k)  
VR5 (1k)  
0
0
0
0
1
0
0
1
1
0
0
1
0
1
0
1/10  
1/100  
1/1000  
1/10000  
60.000V  
600.00V  
1000.0V  
Frequency range control for ACV+Hz(%) mode  
FQ2 FQ1 FQ0 Full Scale Range  
0
0
0
0
0
0
1
1
0
1
0
1
60.00Hz  
600.0Hz  
6.000kHz  
60.00kHz  
20% ~ 80%  
Duty Cycle  
Note: See frequency mode (section 2.8) also  
ALARM bit at voltage mode is used for high crest factor (HCF) signal detection. If MPU  
check the ALARM status flag active when data and range are stable, it should consider the  
making the existing range up to avoid the signal clamping saturation caused by HCF signal.  
There is higher peak voltage with lower RMS value for HCF signal. So if the range is up  
according to the ALARM bit, MCU should set the lower under-limit counts temporarily to  