3.3 DIGIT 3 – DIGIT 0
Digit 3 is the second significant digit on the LCD panel, and digit 0 is the least
significant digit.
Digit
Code
0
1
2
3
4
5
6
7
8
9
0110000
0110001
0110010
0110011
0110100
0110101
0110110
0110111
0111000
0111001
Note:
1. The RS232 code of digit4 is in the packet OPTION1
2. Because the cycle time of measurement for continuity/diode mode is only 50ms, the
least significant digit may not be accurate
3.4 STATUS
The format of this package shown below. The Judge field is meaningful only when the
Function packet indicates Temperature mode. In Temperature mode, judge is 1 if the
unit is °F and is 0 of the unit is °C. Sign field indicates whether the minus sign on the
LCD panel is on or off. BATT field is one when battery low condition is true. OL
indicates input overflow.
0
1
1
Judge
BIT 3
Sign
BIT 2
BATT
BIT1
OL
BIT 0
BIT6
BIT 5
BIT 4
3.5 OPTION 1
0
1
1
UL
BIT 3
Digit4
BIT 0
BIT 6
BIT 5
BIT 4
BIT 2
BIT1
UL field will be 1, only when input frequency is less than 11.1Hz in FR1 range of
frequency mode.
The digit4 field will be 1, when the MSD on the LCD is one.
v1.2
22
11/09/06