4.2 RANGE  
This packet indicates the full scale range of the meter. When the meter operates in  
continuity mode, diode mode, or current (A) mode, this packet is always 0110000 since  
the full scale range in these modes are fixed. The following table lists the code for each  
range in each measurement mode.  
Code  
V
mA  
µA  
Auto A  
4.000 A  
40.00 A 4.000KΩ  
40.00KΩ  
Ω
0110000  
0110001  
0110010  
0110011  
4.000V  
40.00V  
400.0V  
4000V  
40.00mA  
400.0mA  
400.0µA  
4000µA  
400.0Ω  
400.0KΩ  
0110100 400.0mV  
0110101  
4.000MΩ  
40.00MΩ  
0110110  
4.3 DIGIT 3 – DIGIT 0  
Digit 3 is the most significant digit on the LCD panel, and digit 0 is the least significant  
digit. When the LCD panel shows OL, the serial port outputs 4000.  
Digit  
Code  
0
1
2
3
4
5
6
7
8
9
0110000  
0110001  
0110010  
0110011  
0110100  
0110101  
0110110  
0110111  
0111000  
0111001  
Because the cycle time of measurement for continuity/diode mode is only 70ms, the  
least significant digit may not be accurate.  
4.4 STATUS  
The format of this shown below. The Judge field is meaningful only when the Function  
packet indicates Temperature mode. In Temperature mode, judge is 1 if the unit is   
and is 0 of the unit is . Sign field indicates whether the minus sign on the LCD  
panel is on or off. BATT field is one of battery low condition is true. OL indicates input  
overflow.  
0
1
1
Judge  
BIT 3  
Sign  
BIT 2  
BATT  
BIT1  
OL  
BIT 0  
BIT 6  
BIT 5  
BIT 4  
14  