DC field indicates that the meter operates in DC measurement mode, either voltage or
current. AC field indicates that the meter operates in AC measurement mode, either voltage
or current. AUTO field is set to 1 if the meter operates in automatic mode, and is set to 0
when the meter operates in manual mode. SIGN field indicates whether the minus sign of
main measurement on the LCD panel is on or off.
0
1
1
DC
BIT 3
AC
BIT 2
AUTO
BIT 1
SIGN
BIT 0
BIT 6
BIT 5
BIT 4
5.6. OPTION 2
0
1
1
OLM
BIT 3
OLS
BIT 2
-
-
BIT 6
BIT 5
BIT 4
BIT1
BIT 0
OLM bit is 1 when the main measurement mode is over range. OLS bit is 1 when the
sub-measurement mode (Hz or duty) is over range in voltage/current with frequency or
frequency with duty cycle modes.
5.7. OPTION 3
VAHz bit is set to high when the sub-display is available for HZ mode of ACV/ACA. If
MAX/MIN or REL key is pushed actively, the Hz mode will be inactive and the VAHz bit
will be set to low.
0
1
1
-
-
-
VAHz
BIT 0
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
5.8. CR
Carriage return. The transmitted code is 0001101.
5.9. LF
Line feed. The transmitted code is 0001010.
v2.5