PRELIMINARY
Selection Guide
CY62128–55
Maximum Access Time (ns)
Maximum Operating Current
Commercial
L
LL
Maximum CMOS Standby Current
Commercial
L
LL
55
115 mA
70 mA
70 mA
10 mA
100
µA
20
µA
CY62128
CY62128–70
70
110 mA
60 mA
60 mA
10 mA
100
µA
20
µA
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Supply Voltage on V
CC
to Relative GND
[1]
.... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State
[1]
.....................................–0.5V to V
CC
+0.5V
DC Input Voltage
[1]
..................................–0.5V to V
CC
+0.5V
Current into Outputs (LOW) ........................................ 20 mA
Static Discharge Voltage ........................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current ..................................................... >200 mA
Operating Range
Range
Commercial
Ambient
Temperature
[2]
0°C to +70°C
V
CC
5V
±
10%
Electrical Characteristics
Over the Operating Range
[3]
62128–55
Parameter
V
OH
V
OL
V
IH
V
IL
I
IX
I
OZ
I
OS
I
CC
Description
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
[1]
Input Load Current
Output Leakage Current
GND
≤
V
I
≤
V
CC
GND
≤
V
I
≤
V
CC
, Output Disabled
Com’l
L
LL
I
SB1
Automatic CE
Power-Down Current
— TTL Inputs
Automatic CE
Power-Down Current
— CMOS Inputs
Max. V
CC
, CE
1
≥
V
IH
or CE
2
< V
IL
,
V
IN
≥
V
IH
or
V
IN
≤
V
IL
, f = f
MAX
Max. V
CC
,
CE
1
≥
V
CC
– 0.3V,
or CE
2
≤
0.3V,
V
IN
≥
V
CC
– 0.3V,
or V
IN
≤
0.3V, f=0
Com’l
L
LL
Com’l
L
LL
Test Conditions
V
CC
= Min., I
OH
= – 1.0 mA
V
CC
= Min., I
OL
= 2.1mA
2.2
–0.3
–1
–5
Min.
2.4
0.4
V
CC
+
0.3
0.8
+1
+5
–300
115
70
70
25
10
2
10
100
20
2.2
–0.3
–1
–5
Max.
62128–70
Min.
2.4
0.4
V
CC
+
0.3
0.8
+1
+5
–300
110
60
60
25
10
2
10
100
20
Max.
Unit
V
V
V
V
µA
µA
mA
mA
mA
mA
mA
mA
mA
mA
µA
µA
Output Short Circuit Current
[4]
V
CC
= Max., V
OUT
= GND
V
CC
Operating
V
CC
= Max.
,
Supply Current
I
OUT
= 0 mA,
f = f
MAX
= 1/t
RC
I
SB2
Shaded areas contain advance information
Notes:
1. V
IL
(min.) = –2.0V for pulse durations of less than 20 ns.
2. T
A
is the “instant on” case temperature.
3. See the last page of this specification for Group A subgroup testing information.
4. Not more than one output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
2