PRELIMINARY
CYW20713
8.1 Electrostatic Discharge Specifications
Extreme caution must be exercised to prevent electrostatic discharge (ESD) damage. Proper use of wrist and heel grounding straps
to discharge static electricity is required when handling these devices. Always store unused material in its antistatic packaging.
Table 16. ESD Specifications
Types
Symbol
Conditions
ESD Rating
Units
Human body model
ESD_HAND_HBM
Human body model contact discharge
per AEC-Q100-002
3.5
kV
Machine model
ESD_HAND_MM
ESD_HAND_CDM
Machine model contact discharge per
AEC-Q100-003
150
V
V
Charged device
model
Charged device modelcontact discharge
per AEC-Q100-011
500
(750V on corner pins)
Table 17. Pad I/O Characteristicsa
I/O Pad Characteristics
Pad Name
COEX_OUT0
COEX_OUT1
COEX_IN
Pull-Up/Pull-Down
Fail-Safe
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
Y
PCM_CLK
PCM_OUT
PCM_IN
Y
Y
Y
PCM_SYNC
UART_RTS_N
UART_CTS_N
UART_RXD
UART_TXD
GPIO_0
Y
Y
Y
Y
Y
Y
GPIO_1
Y
GPIO_2
Y
GPIO_4
Y
GPIO_7
Y
RST_N
N/A
Y
OTP_DIS
a. All digital I/O internal pull-up or pull-down values are around 60 kΩ.
Document Number: 002-14806 Rev. *C
Page 31 of 52