MGA SERIES
5 WATT
ABSOLUTE MAXIMUM RATINGS
Input Voltage
• 16 to 40 V
Output Power
• 5 watts
Lead Soldering Temperature
• Reflow 220°C 30 sec. max
SN60, 62 or 63 recommended solder
• Hand solder 300°C 10 sec. max. per lead
Storage Temperature Range (Case)
• –65°C to +150°C
DC/DC C
ONVERTERS
INHIBIT
Inhibit: TTL Open Collector
• Logic low (output disabled)
Logic low voltage
≤0.8
V
• Referenced to input common
• Logic high (output enabled)
Open collector
TYPICAL CHARACTERISTICS
Output Voltage Temperature Coefficient
• 100 ppm/°C typ, 150 ppm/C max
Current Limit
• 115% of full load typical
Isolation
• Input to output
• Any pin to case except case pins
• 100 megohm minimum at 500 V
Conversion Frequency
• 500 kHz typical
450 kHz. min, 600 kHz max
Inhibit Pin Voltage (unit enabled)
• 9 to 11 V
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
• 16 to 40 VDC continuous
• 50 V for up to 50 msec transient
Case Operating Temperature (Tc)
• –55°C to +125°C full power
• –55°C to +135°C absolute
Derating Output Power/Current (Tc)
• Linearly from 100% at 125°C to 0% at 135°C
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
SINGLE OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
OUTPUT POWER
OUTPUT RIPPLE
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
CONDITIONS
+V
OUT
V
IN
= 16 to 40 VDC
V
IN
= 16 to 40 VDC
10 kHz - 2 MHz
V
IN
= 16 to 40 VDC
NO LOAD TO FULL
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
FULL LOAD
INHIBITED
INPUT RIPPLE
10 kHz - 10 MHz
EFFICIENCY
LOAD FAULT
1
SHORT CIRCUIT
POWER DISS.
RECOVERY
STEP LOAD
RESPONSE
2
STEP LINE
RESPONSE
4
START-UP
INHIBIT PIN
CURRENT
CAPACITANCE
CAPACITIVE LOAD
INHIBITED
INPUT TO OUTPUT
2.5
50
4.0
300
2.5
40
4.0
500
2.5
60
4.0
500
mA
pF
µF
50% – 100% – 50% LOAD
TRANSIENT
RECOVERY
3
16 – 40 – 16 VDC
TRANSIENT
RECOVERY
3
OVERSHOOT
DELAY
–500
0
0
100
.4
0
10
500
1.0
200
75
–800
0
0
200
0.5
0
10
800
1.3
500
30
–500
0
0
100
0.5
0
10
500
1.3
500
30
mV pk
ms
mV pk
ms
–500
200
200
500
500
–750
300
400
750
1000
–1000
400
400
1000
1000
mV pk
µs
1.5
10
2.0
75
1.2
10
1.9
30
1.2
10
1.8
30
W
ms
Tc = 25°C
Tc = –55°C to +125°C
MIN
4.95
0
16
64
MGA2805S
TYP
5.0
250
10
10
28
27
3
50
75
69
MAX
5.05
1000
5
450
50
50
40
50
60
279
4
200
300
MIN
11.88
0
16
68
MGA2812S
TYP
12
100
10
10
28
29
3
50
75
74
MAX
417
5
500
50
50
40
50
60
263
4
200
300
MIN
0
16
69
MGA2815S
TYP
15
100
10
10
28
31
3
50
75
74
MAX
15.15
333
5
600
50
50
40
50
60
259
4
200
300
%
mA p-p
mA
UNITS
VDC
mA
W
mV p-p
mV
mV
VDC
V
12.12 14.85
Notes
1. Indefinite short circuit protection not guaranteed above 125°C (case).
2. Load transient transition time is >10 µs.
3. Recovery time is measured from application of the transient to the point at
which Vout is within regulation.
4. Input step transition time is >10µs.
B2-82