CY74FCT2374T
8-BIT REGISTER
WITH 3-STATE OUTPUTS
SCCS040A – SEPTEMBER 1994 – REVISED OCTOBER 2001
timing requirements over recommended operating free-air temperature range (unless otherwise
noted) (see Figure 1)
CY74FCT2374T CY74FCT2374AT CY74FCT2374CT
UNIT
MIN
MAX
MIN
MAX
MIN
MAX
t
w
t
su
t
h
Pulse duration, CP
7
5
4
ns
ns
ns
Setup time, data before CP↑
Hold time, data after CP↑
2
2
1.5
1
1.5
1.5
switching characteristics over operating free-air temperature range (see Figure 1)
CY74FCT2374T CY74FCT2374AT CY74FCT2374CT
FROM
(INPUT)
TO
(OUTPUT)
PARAMETER
UNIT
ns
MIN
2
MAX
10
MIN
2
MAX
6.5
6.5
6.5
6.5
5.5
5.5
MIN
2
MAX
5.2
5.2
6.2
6.2
5
t
t
t
t
t
t
PLH
PHL
PZH
PZL
PHZ
PLZ
CP
OE
OE
O
O
O
2
10
2
2
1.5
1.5
1.5
1.5
12.5
12.5
8
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
ns
ns
8
5
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265