欢迎访问ic37.com |
会员登录 免费注册
发布采购

CX28395-19 参数 Datasheet PDF下载

CX28395-19图片预览
型号: CX28395-19
PDF下载: 下载PDF文件 查看货源
内容描述: 四核/ X16 /八路T1 / E1 / J1成帧器 [Quad/x16/Octal?T1/E1/J1 Framers]
分类和应用: 电信集成电路
文件页数/大小: 305 页 / 1863 K
品牌: CONEXANT [ CONEXANT SYSTEMS, INC ]
 浏览型号CX28395-19的Datasheet PDF文件第183页浏览型号CX28395-19的Datasheet PDF文件第184页浏览型号CX28395-19的Datasheet PDF文件第185页浏览型号CX28395-19的Datasheet PDF文件第186页浏览型号CX28395-19的Datasheet PDF文件第188页浏览型号CX28395-19的Datasheet PDF文件第189页浏览型号CX28395-19的Datasheet PDF文件第190页浏览型号CX28395-19的Datasheet PDF文件第191页  
CX28394/28395/28398  
3.0 Registers  
Quad/x16/OctalT1/E1/J1 Framers  
3.12 Transmitter Registers  
AUTO_AIS /TAIS  
Manual/Automatic Transmit Alarm Indication Signal—When activated manually (TAIS) or  
automatically (AUTO_AIS), the alarm formatter replaces all data output on  
TPOSO/TNEGO/TNRZO with an unframed all ones signal (AIS). This includes replacing data  
from the receiver during line loopback [LLOOP; addr 014]. Automatic mode sends AIS for the  
duration of receive loss of signal [RLOS; addr 047]. If AISCLK [addr 075] is enabled, then  
TAIS also provides manual switch control over ACKI clock input. AUTO_AIS does not affect  
ACKI switching.  
AIS transmission [TAIS, AUTO_AIS; addr 075, or AISCLK; addr 075] does not affect  
transmit data that is looped back to the receiver during framer loopback [FLOOP; addr 014].  
This allows both FLOOP and LLOOP to be active simultaneously, during a loss of signal,  
without disrupting data in the framer loopback path.  
TAIS AUTO_AIS AISCLK  
Transmit Data  
Normal, No AIS  
Transmit Clock (TCKO)  
TCKI  
0
0
0
0
1
1
0
0
0
1
0
1
0
1
AIS during TLOC  
TI/EIACKI while TLOC  
AIS During RLOS  
AIS During TLOC or RLOS  
Manual AIS  
1
TCKI  
1
TI/EIACKI while TLOC  
X
X
TCKI  
ACKI  
Manual AIS and ACKI  
NOTE(S): Systems that transmit framed all ones can utilize inband loopback code generator  
[TLB; addr 077] to send all ones in payload only.  
076—Transmit Test Pattern Configuration (TPATT)  
Unused bits are reserved and should be written to 0.  
7
6
5
4
3
2
1
0
TPSTART  
FRAMED  
ZLIMIT  
TPATT[1]  
TPATT[0]  
TPSTART  
FRAMED  
Enable Test Pattern Transmission.  
PRBS Framed—When set, the PRBS pattern does not overwrite framing bit positions and is  
stopped during these bit periods. In T1 mode, the frame bit (every 193 bit) is not overwritten.  
rd  
In E1 mode, the PRBS test pattern is not written to time slot 0 (FAS and NFAS words) and  
time slot 16 (CAS signalling word) if CAS framing is also selected. CAS framing is selected  
by setting TFRAME[3] to 1 in the Transmit Configuration register [TCR0; addr 070]. If  
FRAMED is disabled, the test pattern is transmitted in all time slots.  
ZLIMIT  
Enable Zero Limit; 7/14 depending on pattern.  
TPATT[1:0]  
PRBS test patterns used by RPATT [addr 041] and TPATT [addr 076] are defined in the ITU  
standards O.151 and O.152 to use either inverted or non-inverted data. Standard data inversion  
is used for the selected PRBS test pattern unless ZLIMIT is enabled, in which case the test  
pattern uses non-inverted data (see Table 3-12).  
100054E  
Conexant  
3-65  
 复制成功!