Calling Line Identifier
MX602 - PRELIMINARY INFORMATION
25
4
3.5
3
VtHI
2.5
2
V
IN
VtLO
1.5
1
0.5
0
3
3.5
4
4.5
5
5.5
VDD
Figure 27: Schmitt Trigger typical input voltage thresholds vs. V
DD
10
1
0.1
0.01
µA
0.001
0.0001
-40
-30
-20
-10
0
10
20
30
40
50
60
70
80
Temperature
Figure 28: Typical 'Zero-Power' I vs. Temperature (V = 5.0V)
DD
DD
© 1998 MX•COM Inc.
www.mxcom.com Tele: 800 638-5577 336 744-5050 Fax: 336 744-5054
Doc. # 20480136.004
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA
All trademarks and service marks are held by their respective companies.