型号: MX602DW
PDF下载: 下载PDF文件 查看货源
内容描述: [Telephone Calling No Identification Circuit, CMOS, PDSO16, SOIC-16]
分类和应用: 电信光电二极管电信集成电路
文件页数/大小: 27 页 / 279 K
品牌: CMLMICRO [ CML MICROCIRCUITS ]
 浏览型号MX602DW的Datasheet PDF文件第16页浏览型号MX602DW的Datasheet PDF文件第17页浏览型号MX602DW的Datasheet PDF文件第18页浏览型号MX602DW的Datasheet PDF文件第19页浏览型号MX602DW的Datasheet PDF文件第21页浏览型号MX602DW的Datasheet PDF文件第22页浏览型号MX602DW的Datasheet PDF文件第23页浏览型号MX602DW的Datasheet PDF文件第24页  
Calling Line Identifier  
MX602 - PRELIMINARY INFORMATION  
20  
Mute decision point T1  
Start Timer  
T3, minimum valid DET pulse width  
< 5ms between the falling edge of the DET  
and FSK Mode selection.  
DET pulse width (TDET  
)
TDET  
50ms  
must be > T3 or < 65ms  
to be considered a  
valid DET  
DET monitored for 50ms  
after mode change  
DET  
Not a valid CIDCW transaction  
sequence at this point  
T2, time for muting  
to take affect  
MUTE  
Should a DET pulse occur during  
the 50ms DET monitoring, the pulse  
will last a minimum of 8ms  
TONE / FSK  
MODE  
No Signal  
CAS  
NEAR END  
VOICE  
FAR END  
VOICE  
Note: The actual signal received by the MX602 is the sum of the CAS, Near-End Voice, and Far-End Voice signals.  
Figure 22, Invalid CIDCW Transaction Initiation Adjunct Box Timing Sequence (DET output goes high during  
50ms quiet period)  
Mute decision point T1 = 0 (no hold-off)  
T3, minimum valid DET pulse width  
Start Timer  
< 5ms between the falling edge of the DET  
and FSK Mode selection.  
DET pulse width (TDET  
)
TDET  
must be > T3 or < 65ms  
to be considered a  
valid DET  
50ms  
DET monitored for 50ms  
after mode change  
DET  
T2, time for muting to take affect  
MUTE  
0.5ms to 10ms from end of CAS to DET falling edge  
TONE / FSK  
MODE  
Initiate CIDCW  
transaction  
sequence  
75ms < TCAS < 85ms  
at this point  
CAS  
NEAR END  
VOICE  
FAR END  
VOICE  
Note: The actual signal received by the MX602 is the sum of the CAS, Near-End Voice, and Far-End Voice signals.  
Figure 23: Valid CIDCW Transaction Initiation Telephone Set Timing Sequence  
© 1998 MXCOM Inc.  
www.mxcom.com Tele: 800 638-5577 336 744-5050 Fax: 336 744-5054  
Doc. # 20480136.004  
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA  
All trademarks and service marks are held by their respective companies.  
 复制成功!