Quad Digital Control Amplifier  
5
MX019  
3. External Components  
V
DD  
V
SERIAL CLOCK INPUT  
LOAD/LATCH  
DD  
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
C
CONTROL DATA INPUT  
CHIP ADDRESS  
6
LOAD/LATCH  
CHANNEL 1 INPUT  
CHANNEL 1 OUTPUT  
CHANNEL 2 OUTPUT  
C
C
C
C
1
2
3
4
CHANNEL 2 INPUT  
CHANNEL 3 INPUT  
CHANNEL 4 INPUT  
MX019J  
CHANNEL 3 OUTPUT  
CHANNEL 4 OUTPUT  
V
V
BIAS  
SS  
C
5
C1 to C4  
C5  
0.1µF  
1.0µF  
1.0µF  
± 20%  
± 20%  
± 20%  
C6  
Figure 2: Recommended External Components  
Notes:  
1. Channel Amplifiers 1 to 4 are inverting amplifiers.  
2. Analog input capacitors C1 to C4 are only required for AC input signals, DC input signals do not  
require these components.  
4. General Description  
4.1 Control Data and Timing  
The gain of each amplifier block (Channel 1 to Channel 4) in the MX019 is set by a separate 8-bit data word  
(bit 7 to bit 0). This 8-bit word, consisting of 4 Address bits (bit 7 to bit 4) and 4 Gain Control bits (bit 3 to bit  
0), is loaded to the Control Data Input in serial format using the external data clock.  
4.1.1 Data Loading  
The 8-bit data word is loaded bit 7 first and bit 0 last.  
Bit 7 must be a logic “1” to address the chip.  
If bit 7 in the word is a logic “0” that 8-bit word will not be executed. The Chip Address input permits the use of  
two devices in a system by indicating to the chip what its address is, a “1” or a “0.” Bit 6 in the address section  
of the control word is then used to select which device is being controlled. Figure 3 shows the timing  
information required to load and operate this device.  
Data is loaded to the MX019 on the rising edge of the Serial Clock. Loaded data is executed on the falling  
(rising) edge of the Load/Latch (Load /Latch) pulse.  
Table 1 shows the format of each 4-bit Address word, Table 2 shows the format of each Gain Control word  
with Figure 3 describing the data loading operation and timing.  
1998 MX-COM, INC.  
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA  
www.mxcom.com Tel: 800 638 5577 910 744 5050 Fax: 910 744 5054  
Doc. # 20480077.006  
All trademarks and service marks are held by their respective companies  