欢迎访问ic37.com |
会员登录 免费注册
发布采购

CMX7163Q1 参数 Datasheet PDF下载

CMX7163Q1图片预览
型号: CMX7163Q1
PDF下载: 下载PDF文件 查看货源
内容描述: [Modem, VQFN-64]
分类和应用: 电信电信集成电路
文件页数/大小: 81 页 / 4386 K
品牌: CMLMICRO [ CML MICROCIRCUITS ]
 浏览型号CMX7163Q1的Datasheet PDF文件第31页浏览型号CMX7163Q1的Datasheet PDF文件第32页浏览型号CMX7163Q1的Datasheet PDF文件第33页浏览型号CMX7163Q1的Datasheet PDF文件第34页浏览型号CMX7163Q1的Datasheet PDF文件第36页浏览型号CMX7163Q1的Datasheet PDF文件第37页浏览型号CMX7163Q1的Datasheet PDF文件第38页浏览型号CMX7163Q1的Datasheet PDF文件第39页  
CMX7163 QAM Modem  
CMX7163  
The CMX998 Cartesian Feed-back Loop Transmitter datasheet and an application note “CMX998  
Cartesian Feedback Loop dc Calibration” are both available from the CML website (www.cmlmicro.com)  
and should be referred to for a more in-depth understanding of the need for dc offset calibration.  
The CMX7163 performs automatic dc offset calibration as either part of a transmit sequence or in a  
separate calibration stage. DC offset calibration determines the dc offset that should be applied to the I  
Output and Q Output signals by the CMX7163 to minimise carrier leakage. The results of calibration will be  
held by the CMX7163 for use in later transmissions and are made available to the host. The interface is  
required to be as shown in Figure 16 CMX998 DC Calibration Interfaces.  
I Input  
I Output  
A
A
Q Input  
Q Output  
AuxADC2  
DCMEAS  
B
CMX998  
CMX7163  
SPI Thru-Port  
(Chip Sel = SSOUT1)  
C-BUS In  
PA Cntrl  
C
D
AuxDAC1 (RAMDAC)  
A. The CMX7163 I and Q Outputs are used to provide dc levels, which are adjusted to make the error I/Q  
measurements equal to the Reference I/Q measurements  
B. AuxADC2 is used to sample DCMEAS To measure Reference signals and error signals  
C. The SPI Thru-Port is used to control the CMX998 selecting Reference I/Q and Error I/Q as measurements,  
as well as high gain/low gain modes of the CMX998  
D. The RAMDAC is typically used to ramp the PA Control voltage up after calibration is complete. This is not a  
part of the calibration sequence, but may be active as part of the transmit sequence.  
Figure 16 CMX998 DC Calibration Interfaces  
During calibration the CMX998 is controlled by the CMX7163 using the SPI Thru-Port (The CMX998 is  
assumed to be device 1) to select one of the following to be output to the CMX998 DCMEAS output:  
I Reference  
Q Reference  
I Error (Low/high gain )  
The CMX998 dc reference for the In-phase signal path  
The CMX998 dc reference for the Quadrature signal path  
The CMX998 measure of the dc produced by the input signal on the In-  
phase signal path  
2
Q Error (Low/high gain)  
The CMX998 measure of the dc produced by the input signal on the  
Quadrature signal path  
During calibration the CMX7163 uses AuxADC2 to measure Reference I and Reference Q. It then outputs  
a dc level on the I Output, Q Output signals. AuxADC2 is used to measure the DCMEAS I and Q Error and  
I Output, Q Output are adjusted to make the DCMEAS I and Q errors equal to the DCMEAS I Reference  
and Q Reference measurements.  
2
The low and high gain states are created by adjusting the gain of the error amplifiers in the CMX998, see  
the CMX998 datasheet for more information.  
2014 CML Microsystems Plc  
Page 35  
D/7163_FI-4.x/12