Functional Descriptions ......  
The CM1481 can be configured to one of two modes of user control.  
Single or  
Dual Button  
Operation  
Dual Button mode. The ‘Quiet/Open’ switch toggles the ‘Quiet/Open’ (mute) function; the  
‘Tx Call’ switch initiates a Selcall ‘Tx Call’.  
If it is required to operate in a unit with no local means of ‘Quiet/Open’ operation, this  
dual-button mode should be configured but the ‘Quiet/Open’ input not connected  
internally.  
Single Button mode. A single switch (push-button) connected to either ‘Quiet/Open’ or  
‘Tx Call’ inputs controls both Mute and Selcall operations.  
A “press” of less than 1-second will toggle the ‘Quiet/Open’ condition; a “press” of more  
than 1-second will initiate a Selcall.  
Both inputs can be configured to active “High” or “Low” polarities; with reference to the  
CM1481, both inputs are connected, on-board, to the positive supply rail (VDD) via 47kΩ  
pullup resistors.  
For an active “Low” input, the switches should be connected directly to 0V (GND).  
For an active “High” requirement, the on-board pullup resistors must be considered.  
Configured as Operation:  
+ve  
supply rail  
Quiet/Open  
Tx Call  
pullup resistors  
Fig.7 Operating Button Connections  
Each unit is assigned a unique ANI code which enables identification of a transmission. In  
the CM1481 this code is programmable, both by initial configuration and by over-air  
re-configuration, as the ANI address.  
Automatic  
Number  
Identification  
(ANI)  
When enabled the ANI code is transmitted at the beginning (leading) and/or the end  
(trailing) of a transmission. In the CM1481 the ANI operation is selectable by configuration  
to either OFF, Lead, Trail, or Lead and Trail.  
If the PTT Time-Out function is activated, a trailing ANI (if configured) is transmitted  
before shut-down.  
Configured as ANI Mode: and ANI Address:  
Mic key reset; signifying  
end of conversation  
PTT In  
(active "low")  
Tx remains keyed  
for ANI period  
Tx ON  
(active "low")  
Tone Out  
Leading  
ANI  
Trailing  
ANI  
Fig.8 ANI Functional Diagram  