CPC7583  
2. Functional Description  
2.1 Introduction  
The CPC7583 has the following states:  
minimize the stress on the solid-state contacts, use of  
a foldback or crowbar type secondary protector is  
recommended. With proper selection of the secondary  
protector, a line card using the CPC7583 will meet all  
relevant ITU, LSSGR, TIA/EIA and IEC protection  
requirements.  
Talk. Loop break switches SW1, and SW2 closed, all  
other switches open.  
Ringing. Ringing switches SW3, SW4 closed, all  
other switches open.  
TESTout. Testout switches SW5, SW6 closed, all  
other switches open.  
Ringing generator test. SW7, SW8 closed, all  
other switches open.  
TESTin. Testin switches SW9 and SW10 closed.  
Simultaneous TESTin and TESTout. SW9, SW10,  
SW5, and SW6 closed, all other switches open.  
Simultaneous test out and ringing generator  
test. SW5, SW6, SW7, and SW8 closed, all other  
switches open (only on the xC and xD versions).  
All Off. All switches open.  
The CPC7583 operates from a +5 V supply only. This  
gives the device extremely low idle and active power  
consumption and allows use with virtually any range of  
battery voltage. The battery voltage is also used by the  
CPC7583 as a reference for the integrated protection  
circuit. In the event of a loss of battery voltage, the  
CPC7583 enters the all-off state.  
2.2 Switch Logic  
The CPC7583 provides, when switching from the  
ringing state to the talk state, the ability to control the  
release timing of the ringing switches SW3 and SW4  
relative to the state of the loop break switches SW1  
and SW2 using simple logic-level input. This is  
referred to as a make-before-break or  
break-before-make operation. When the line break  
switch contacts (SW1 and SW2) are closed (or made)  
before the ringing access switch contacts (SW3 and  
SW4) are opened (broken), this is referred to as  
make-before-break operation. Break-before-make  
operation occurs when the ringing access contacts  
(SW3 and SW4) are opened (broken) before the line  
break switch contacts (SW1 and SW2) are closed  
(made). With the CPC7583, the make-before-break  
and break-before-make operations can easily be  
selected by applying the proper sequence of logic  
See “Truth Tables” on page 12 for more information.  
The CPC7583 offers break-before-make and  
make-before-break switching from the ringing state to  
the talk state with simple logic level input control.  
Solid-state switch construction means no impulse  
noise is generated when switching during ringing  
cadence or ring trip, eliminating the need for external  
zero-cross switching circuitry. State-control is via  
logic-level input so no additional driver circuitry is  
required. The linear line break switches SW1 and  
SW2 have exceptionally low R and excellent  
ON  
matching characteristics. The ringing switch SW4 has  
a minimum open contact breakdown voltage of 465 V.  
This is sufficiently high, with proper protection, to  
prevent breakdown in the presence of a transient fault  
condition (i.e., passing the transient on to the ringing  
generator).  
inputs to IN  
, IN  
, and IN  
.
TESTout  
RINGING  
TESTin  
The logic sequences for either mode of operation are  
given in “Make-Before-Break Operation (Ringing to Talk  
Transition)” on page 15 and “Break-Before-Make Operation  
(Ringing to Talk Transition)” on page 15. Logic states and  
explanations are given in “Truth Tables” on page 12.  
Integrated into the CPC7583 is an over voltage  
clamping circuit, active current limiting, and a thermal  
shutdown mechanism to provide protection to the  
SLIC device during a fault condition. Positive and  
negative surges are reduced by the current limiting  
circuitry and hazardous potentials are diverted to  
ground via diodes and the integrated SCR.  
Break-before-make operation can also be achieved  
using the T pin as an input. In “Break-Before-Make  
SD  
Operation (Ringing to Talk Transition)” on page 15, lines 2  
and 3, it is possible to induce the switches to the all-off  
Power-cross potentials are also reduced by the current  
limiting and thermal shutdown circuits.  
state by grounding T instead of applying input to the  
SD  
logic pins. This has the effect of overriding the logic  
inputs and forcing the device to the all-off state. For  
To protect the CPC7583 from an overvoltage fault  
condition, the use of a secondary protector is required.  
The secondary protector must limit the voltage seen at  
the T  
and R  
terminals to a level below the  
LINE  
LINE  
maximum breakdown voltage of the switches. To  
14  
www.clare.com  
R06  