CPC75282
1.4 Absolute Maximum Ratings
1.5 ESD Rating
ESD Rating (Human Body Model)
1000V
Parameter
+5V power supply (V
Battery Supply
Minimum Maximum
Unit
)
-0.3
-
7
V
V
V
V
DD
-85
+5
D
to F
Separation
-5
GND
GND
1.6 General Conditions
V
+ 0.3
Logic input voltage
-0.3
DD
Logic input to switch output
isolation
Unless otherwise specified, minimum and maximum
values are production testing requirements. Typical
values are characteristic of the device and are the
result of engineering evaluations. They are provided
for information purposes only and are not part of the
testing requirements.
-
-
-
320
320
465
V
V
V
Switch open-contact
isolation (SW1, SW2, SW3,
SW5, SW6)
Switch open-contact
Isolation (SW4)
Specifications cover the operating temperature range
Operating relative humidity
Operating temperature
Storage temperature
5
95
%
T = -40°C to +85°C. Also, unless otherwise specified,
-40
-40
+110
+150
°C
°C
A
all testing is performed with V = 5V , logic low
DD
DC
input voltage is 0V and logic high voltage is 5V
.
DC
DC
Absolute maximum electrical ratings are at 25°C.
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
4
www.clare.com
R00D