CPC1465
1.4 Electrical Characteristics
Unless otherwise specified, minimum and maximum
values are guaranteed by production testing
informational purposes only and are not part of the
testing requirements.
requirements. Typical values are characteristic of the
device and are the result of engineering evaluations.
In addition, typical values are provided for
All electrical specifications are provided for T =25°C
A
1.4.1 DC Characteristics, Normal Operation
For operational templates: (see Figure 2 on page 5) and (see Figure 3 on page 5).
Parameter
Activate/Non-activate Voltage
Breakover current
Conditions Symbol Minimum Typical Maximum
Unit
V
V
Off State
30.0
35.0
0.5
39.0
1
AN
I
-
-
-
mA
V
BO
Active State, 1 mA ≤ I ≤ 20 mA
SL
V
ON
DC Voltage drop
12.5
1.5
15
5
V
= 20 V
I
LKG
DC leakage current
Hold/Release current
Minimum on current
-
μA
mA
mA
OFF
I
Active State
< 54 V
0.1
20
0.5
1.0
-
H/R
V
I
I
I
38
ON
MIN1
MIN2
MIN3
54 V ≤ V ≤ 100 V for 2 seconds,
source resistance 200 Ω to 4 kΩ
ON
Minimum on current
9.0
45
-
mA
V
> 100 V
Minimum on current
Maximum on current
0
-
0.1
-
mA
mA
ON
V
≤ 70 V
I
38.4
70
ON
MAX1
MAX2
VON
V
> 70 V
I
Maximum on current
-
-
mA
mA
-----------
ON
1kΩ
I
Photodiode drive current
Active State
0.2
0.3
10
PD
1.4.2 AC Characteristics, Normal Operation
For test conditions: (see Figure 4 on page 6) and (see Figure 5 on page 6).
Parameter
ac impedance
Conditions
200 Hz to 50 kHz
Symbol Minimum
Typical Maximum
Unit
Z
-
10
MT
38
kΩ
f = 200 Hz to 40 kHz, I = 1 mA to
SL
Linearity distortion
Linearity distortion
D1
D2
75
50
78
70
-
-
dB
dB
20 mA, V ≤ 10.5 V
APP
PP
f = 200 Hz to 40 kHz, I = 1 mA to
SL
20 mA, V ≤ 12 V
APP
PP
1.4.3 Transition Characteristics, Normal Operation
For activation/deactivation test conditions: (see Figure 6 on page 7).
Parameter
Conditions
Symbol Minimum
Typical Maximum
Unit
Activate time
Deactivate time
(see Figure 7 on page 7)
(see Figure 8 on page 7)
t1
t2
3.0
3.0
13
-
50
ms
ms
100
4
www.clare.com
R02