CS42416  
6.10 Volume Transition Control (address 0Dh)  
7
6
5
4
3
2
1
0
Reserved  
SNGVOL  
SZC1  
SZC0  
AMUTE  
MUTE  
ADC_SP  
RAMP_UP  
RAMP_DN  
6.10.1 SINGLE VOLUME CONTROL (SNGVOL)  
Default = 0  
Function:  
The individual channel volume levels are independently controlled by their respective Volume Control  
registers when this function is disabled. When enabled, the volume on all channels is determined by  
the A1 Channel Volume Control register and the other Volume Control registers are ignored.  
6.10.2 SOFT RAMP AND ZERO CROSS CONTROL (SZCX)  
Default = 00  
00 - Immediate Change  
01 - Zero Cross  
10 - Soft Ramp  
11 - Soft Ramp on Zero Crossings  
Function:  
Immediate Change  
When Immediate Change is selected, all level changes will take effect immediately in one step.  
Zero Cross  
Zero Cross Enable dictates that signal-level changes, either by attenuation changes or muting, will  
occur on a signal zero crossing to minimize audible artifacts. The requested level-change will occur  
after a timeout period between 512 and 1024 sample periods (10.7 ms to 21.3 ms at 48 kHz sample  
rate) if the signal does not encounter a zero crossing. The zero cross function is independently mon-  
itored and implemented for each channel.  
Soft Ramp  
Soft Ramp allows level changes, both muting and attenuation, to be implemented by incrementally  
ramping, in 1/8 dB steps, from the current level to the new level at a rate of 1 dB per 8 left/right clock  
periods.  
Soft Ramp on Zero Crossing  
Soft Ramp and Zero Cross Enable dictates that signal level changes, either by attenuation changes  
or muting, will occur in 1/8 dB steps and be implemented on a signal zero crossing. The 1/8 dB level  
change will occur after a timeout period between 512 and 1024 sample periods (10.7 ms to 21.3 ms  
at 48 kHz sample rate) if the signal does not encounter a zero crossing. The zero cross function is  
independently monitored and implemented for each channel.  