CDB61880
2.9 Line Length/Impedance Selection
2.11 G.772 Monitoring Address Selection
In Hardware mode, switch S11 (CBLSEL) is used
In Hardware mode, the address for the G.772 Non-
to set the internal or external line impedance for all Intrusive monitoring feature is selected by switches
eight channels. The CBLSEL switch is also used to 3 through 7 (A4-A0) inside switch block S9. When
select the desired pulse shape to be transmitted by
the device. Refer to the CS61880 Data Sheet for the
CBLSEL settings.
switches 3 through 7 inside switch block S9 are all
set to the closed “LOW” position, the G.772 Non-
Intrusive monitoring function is disabled. Refer to
the CS61880 Data Sheet for more address settings.
In Host mode, switch S11 has no effect on the
CS61880 device and should be set to the NC (mid- In Host mode, switches 3 through 7 inside switch
dle) position.
block S9 must be set to the open (high) position so
that the host interface can have control over the ad-
dress signals during Parallel Host modes.
2.10 Coder/Motorola/Intel Selection
In Hardware mode, switch 1 (MOT/INTL) inside
switch block S9 (S9 #1) is used to enable AMI or
HDB3 line coding. Setting switch S9 #1 to the open
(HIGH) position enables AMI coding and the
closed (low) position enables HDB3 coding.
2.12 Mux/Non-Mux/BITS Clock Selection
In Hardware mode, switch 2 (MUX) inside switch
block S9 enables or disables the Channel #0 G.703
BITS Clock function. Placing switch S9 #2 in the
open “HIGH” position enables Channel #0 G.703
BITS Clock function and the closed “LOW” posi-
tion disables this function.
In Host mode, switch S9 #1 is used to select either
Motorola or Intel Parallel Host mode. When set to
the open (HIGH) position Intel mode is selected
and the closed (LOW) position enables Motorola
mode. Figure 9 shows the settings for switch S9 #1
in Hardware and Parallel Host mode.
In Host mode, switch S9 #2 (MUX) is used to select
multiplex or non-multiplex. Placing switch S9 #2
in the open “HIGH” position selects multiplex and
the closed “LOW” position selects Non-multiplex.
S9
S9
S9
A0
A0
A0
A1
A1
A1
A2
A2
A2
A3
A3
A3
A4
A4
A4
MUX
MUX
MUX
MOT_\INTL
MOT_\INTL
MOT_\INTL
LO
HI
LO
HI
LO
HI
Parallel Host Mode -
Hardware Mode - Enables
AMI coding & enables
Channel 0 G.703 Bits
Clock function
Hardware Mode - Enables
HDB3/B8ZS coding &
disables Channel 0 G.703 Bits
Clock function
Enables Motorola Non-
Multiplex parallel host mode
Figure 9. Switch S9 Settings