欢迎访问ic37.com |
会员登录 免费注册
发布采购

CDB4222 参数 Datasheet PDF下载

CDB4222图片预览
型号: CDB4222
PDF下载: 下载PDF文件 查看货源
内容描述: 20位立体声音频编解码器与音量控制 [20-Bit Stereo Audio Codec with Volume Control]
分类和应用: 解码器编解码器
文件页数/大小: 26 页 / 579 K
品牌: CIRRUS [ CIRRUS LOGIC ]
 浏览型号CDB4222的Datasheet PDF文件第8页浏览型号CDB4222的Datasheet PDF文件第9页浏览型号CDB4222的Datasheet PDF文件第10页浏览型号CDB4222的Datasheet PDF文件第11页浏览型号CDB4222的Datasheet PDF文件第13页浏览型号CDB4222的Datasheet PDF文件第14页浏览型号CDB4222的Datasheet PDF文件第15页浏览型号CDB4222的Datasheet PDF文件第16页  
CS4222  
change is adjustable to 4, 16, or 32 LRCK cycles  
with the RMP1/0 bits in the DAC control byte  
(#2).  
they receive between 512 and 1024 consecutive  
zeros (or -1 code). Detection and muting is done  
independently for left and right channels. A sin-  
gle non-zero value will immediately unmute the  
DAC output. This feature is enabled on power-  
up, and it may be disabled with the MUTC bit in  
the DAC Control Byte (#2).  
"Soft" volume control may be disabled through  
the SOFT bit in the DAC bit Control Byte (#2).  
When "soft" volume control is defeated, level  
changes step from the current level to the new  
level in a single step. The volume change takes  
effect on a zero crossing to minimize audible ar-  
tifacts. If there is no zero crossing, then the  
requested level change will occur after a time-  
out period between 512 and 1024 sample periods  
(10.7 ms to 21.3 ms at 48 kHz sample rate).  
There is a separate zero crossing detector for  
each channel. ACCR and ACCL bits in the Con-  
verter Status Report Byte (#6) give feedback on  
when a volume control change has taken effect  
for the right and left channel. This bit goes high  
when a new setting is loaded and returns low  
when it has taken effect.  
Master Clock Generation  
The Master Clock, MCLK, is used to operate the  
digital filters and the delta-sigma modulator.  
MCLK must be either 256x, 384x, or 512x the  
desired Input Sample Rate, Fs. Fs is the fre-  
quency at which digital audio samples for each  
channel are input to the DAC or output from the  
ADC and is equal to the LRCK frequency. The  
MCLK to LRCK frequency ratio is detected  
automatically during the initialization sequence by  
counting the number of MCLK transitions during  
a single LRCK period. Internal dividers are then  
set to generate the proper clocks for the digital  
filters, delta-sigma modulators and switched-ca-  
pacitor filter. Table 3 illustrates the standard  
audio sample rates and the required MCLK fre-  
quencies. If MCLK stops for 10µs, the CS4222  
will enter a power down state until the clock re-  
turns. The control port registers will maintain  
their current settings. It is required to have  
SCLK and LRCK derived from the master clock.  
Soft Mute/Mute on Zero Input Data  
Muting can be achieved via hardware or soft-  
ware control. Soft mute can be achieved by  
lowering the SMUTE pin at which point the out-  
put level will ramp down in 0.5 dB steps to a  
muted state. Upon returning the SMUTE pin  
high, the output will ramp up to the volume con-  
trol setting in the Output Attenuator Data Bytes  
(#3 & #4). "Soft" mute may be disabled through  
the SOFT bit in the DAC Control Byte (#2).  
When "soft" mute is defeated, muting occurs on  
zero crossings or after a time-out period, similar  
to the volume control changes.  
Fs (kHz)  
MCLK (MHz)  
384x  
256x  
512x  
32  
44.1  
48  
8.1920  
11.2896  
12.2880  
12.2880  
16.9344  
18.4320  
16.3840  
22.5792  
24.5760  
Table 3. Common Clock Frequencies  
Under software control, each output can be inde-  
pendently muted via mute control bits, MUTR  
and MUTL, in the DAC Control Byte (#2). Soft  
mute or zero crossing mute will be implemented  
depending on the state of the SOFT bit in the  
DAC Control Byte (#2).  
Muting on consecutive zero input data is also  
provided where all DAC outputs will mute if  
12  
DS236PP3