4
G-Series Circuit Breaker - DIN Rail – UL Recognized – Ordering Scheme
G A 1 B 0 24 620 1 1 D C
8
9
10
Rating
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color &
Legend
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
1 SERIES
G
8 TERMINAL
1
Screw Terminal
2 ACTUATOR
9 ACTUATOR COLOR & LEGEND
A
S
Handle, one per pole
Actuator Color
White
I-O
A
C
F
H
K
M
P
ON-OFF
Dual
Legend Color
Black
Mid-Trip Handle, one per pole
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
Red
White
Green
Blue
White
3 POLES
L
White
1
2
One
Two
3
4
Three
Four
Yellow
Gray
Orange
N
Q
S
Black
Black
R
Black
4 CIRCUIT
1
A
B
Switch Only (no coil)
Series Trip (current)
10 APPLICATION RATING
5
B
D
H
M
125 VDC
240 VAC
480 VAC
80 VDC
4
3
5 AUXILIARY / ALARM SWITCH
0
1
3
5
6
without Aux Switch
S.P.D.T., Screw Terminal
S.P.D.T. Screw Terminal (Gold Contacts)
Plug-in Terminal
Plug-in Terminal (Gold Contacts)
11 AGENCY APPROVAL
A
C
E
Without Approvals
UL Recognized, CSA Accepted
UL Recognized, CSA Accepted, TUV Certified, CCC Certified
6 FREQUENCY & DELAY
03 Switch Only
10 DC, Instantaneous
11 DC, Ultra Short
12 DC, Short
14 DC, Medium
16 DC, Long
20 50/60 Hz Instantaneous
21 50/60 Ultra Short
22 50/60 Hz Short
24 50/60 Hz Medium
Notes:
26 50/60 Hz Long
1
Switch only circuit only available when tied to a protected pole (Circuit code B)
- for .2 to 30 amps select current code 630
2
42 50/60 Hz High-inrush Short
44 50/60 Hz High-inrush Medium
46 50/60 Hz High-inrush Long
52 DC High-inrush Short
- for 31 to 50 amps select current code 650
- for 51 to 63 amps select current code 663
- Use delay 03 for all switch only poles
2
3
Hi Inrush Delays limited to 50A max
54 DC High-inrush Medium
56 DC High-inrush Long
On multi-pole breakers one auxiliary switch is supplied , mounted in the extreme
left pole when viewed from front of panel
480 VAC rating requires 3 or 4 pole break 3Φ and 2 pole break 1Φ
This construction is polarity sensitive when constructed as a single pole unit,
125 VDC is only available without agency approvals
4
5
7 CURRENT RATING (AMPERES)
CODE AMPERES
210 0.100
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
655 55.000
660 60.000
663 63.000
Email: sales@carlingtech.com Application Support: team2@carlingtech.com