22
A-Series Circuit Breaker - Flat Rocker UL Recognized – Ordering Scheme
A 1 1 B 0 24 630 2 3 1 E
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
11
8 TERMINAL
1 SERIES
A
12
13
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
E
F
Screw M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
13
13
1
2 ACTUATOR
Two Color Visi-Rocker
G
H
L
M
P
Q
R
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Stud
13
14
13
15
1
2
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Single color
7
8
9
Screw 8-32 (Bus Type)
& 30° bend
Printed Circuit Board Terminals
Push-In Stud
3
4
Vertical legend
Horizontal legend
Screw 10-32 with upturned lugs
& 30° bend
Screw M4 with upturned lugs
& 30° bend
Push-To-Reset, Visi-Rocker
16
5
6
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Screw 10-32 (Bus Type)
& 30° bend
S
T
Push-On 0.110 Tab (Q.C.)
& 30° bend
Push-To-Reset , Single color
B
C
Screw M5 with upturned lugs
Screw M4 with upturned lugs
Screw M4 (Bus Type)
& 30° bend
7
8
Vertical legend
Horizontal legend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
2
17
17
3 POLES
One
Visi-Color
White
Black
ON-OFF
Dual
Single Color Visi-Rocker
1
2
Two
3
Three
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
Red
Red
4
4
4,5
4 CIRCUIT
F
Relay Trip (Current)
Relay Trip (Voltage)
Green
Blue
Green
Blue
3
A
B
C
D
E
Switch Only (No Coil)
G
H
L
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Yellow
Gray
N
Q
S
Yellow
Gray
Orange
4
4
4,5
K
Dual Coil with Relay Trip
Voltage Coil
Orange
18
10 MOUNTING / BARRIERS
6,7
5 AUXILIARY / ALARM SWITCH
5
7
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
6-32 x 0.195 inches
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
BARRIERS
0
1
2
4
without Aux Switch
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
1
no
8
9
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
A
2
yes
no
B
ISO M3 x 5mm (multi-pole units only)
RECESSED OFF SIDE ROCKER ACTUATOR
6-32 x 0.195 inches
yes
19
6 FREQUENCY & DELAY
5
E
6
F
no
03 DC 50/60Hz, Switch Only
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
6
10 DC Instantaneous
11
DC Ultra Short
ISO M3 x 5mm (multi-pole units only)
yes
12 DC Short
14 DC Medium
16 DC Long
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
3
6-32 x 0.195 inches
no
9
9
9
9
42 50/60Hz Short, High-inrush
C
4
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
ISO M3 x 5mm (multi-pole units only)
yes
no
6
20 50/60Hz Instantaneous
44 50/60Hz Medium, High-inrush
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
46 50/60Hz Long, High-inrush
D
yes
52 DC, Short, High-inrush
9
54 DC, Medium, High-inrush
56 DC, Long, High-inrush
11 AGENCY APPROVAL
C
E
I
UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
7 CURRENT RATING (AMPERES)
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
Notes:
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or
mixed poles, and have one rocker per breaker.
3
Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected
pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for Dual Coil options, as special catalog number is required. With Shunt
construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA
minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with
standard half shells. 30-50A are supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
Available with Circuit Codes B & D only. UL Recognized, CSAAccepted & TUV Certified to 50 amps.
4
5
6
7
8
9
8
635 35.000
10 UL Recognition, CSAAcceptance & TUV Certification available in one and two pole breakers.
11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are
only available with Terminal Codes 5, 9, G, H, M and Q.
12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps.
13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal
Code M (M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers
are only TUV Certified when the washers are used.
8
640 40.000
8
645 45.000
8
650 50.000
8
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
14 TUV Cert. available up to 12 amps. UL Rec. & CSAAccepted available up to 30 amps.
15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps
with UL Recognition, CSAAccepted & TUV Certification, with Circuit Codes A, B and C. Two
pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL
Recognition and CSA Accepted with Circuit Codes A, B and C.
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
J06
6 AC
16 Terminal Code S used on voltage coil circuit constructions only.
17 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend.
18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend
on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6.
19 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available
in ink stamping only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com