CM1223
(SEE NOTE 1)
ELECTRICAL OPERATING CHARACTERISTICS
SYMBOL PARAMETER
CONDITIONS
MIN
TYP
MAX UNITS
VP
IP
Operating Supply Voltage (VP-VN)
Operating Supply Current
3.3
5.5
8.0
V
(VP-VN)=3.3V
μA
VSCL
Signal Clamp Voltage
Positive Transients
Negative Transients
IF = 8mA; TA=25°C
6.7
0.60
8.2
0.80
V
V
ILEAK
CIN
Channel Leakage Current
Channel Input Capacitance
TA=25°C; VP=5V, VN=0V
0.1
1.0
1.0
1.5
μA
At 1 MHz, VP=3.3V, VN=0V, VIN=1.65V;
Note 2 applies
pF
Channel Input Capacitance
Matching
At 1 MHz, VP=3.3V, VN=0V, VIN=1.65V;
Note 2 applies
0.02
0.11
pF
pF
ΔCIN
CMUTUAL Mutual Capacitance between sig- At 1 MHz, VP=3.3V, VN=0V, VIN=1.65V;
nal pin and adjacent signal pin
Note 2 applies
VESD
ESD Protection
Peak Discharge Voltage at any
channel input, in system
a) Contact discharge per
IEC 61000-4-2 standard
b) Human Body Model,
MIL-STD-883, Method
3015
Notes 2, 4 & 5; TA=25°C
Notes 2, 3 & 5; TA=25°C
8
kV
kV
15
VCL
Channel Clamp Voltage
Positive Transients
TA=25°C, IPP = 1A, tP = 8/20uS;
Notes 2 & 5
+8.8
-1.4
V
V
Negative Transients
RDYN
Dynamic Resistance
Positive Transients
Negative Transients
TA=25°C, IPP = 1A, tP = 8/20uS
Any I/O pin to Ground; Notes 2 & 5
0.7
0.4
Ω
Ω
Note 1: All parameters specified at TA = -40°C to +85°C unless otherwise noted.
Note 2: These parameters guaranteed by design and characterization.
Note 3: Human Body Model per MIL-STD-883, Method 3015, CDischarge = 100pF, RDischarge = 1.5KΩ, VP = 3.3V, VN grounded.
Note 4: Standard IEC 61000-4-2 with CDischarge = 150pF, RDischarge = 330Ω, VP = 3.3V, VN grounded.
Note 5: These measurements performed with no external capacitor on VP (VP floating).
© 2006 California Micro Devices Corp. All rights reserved.
08/02/06
490 N. McCarthy Blvd., Milpitas, CA 95035-5112
●
Tel: 408.263.3214
●
Fax: 408.263.7846
●
www.cmd.com