Data Sheet
Electrical Characteristics continued
T
A
= 25°C (if
bold,
T
A
= -40 to +85°C), V
s
= +5V, -V
s
= GND, R
f
= R
g
=2kΩ, R
L
= 2kΩ to V
S
/2, G = 2; unless otherwise
noted.
Symbol
I
SOURCE
Parameter
Output Current, Sourcing
(1)
Conditions
V
IN+
= 1V, V
IN-
= 0V, +V
S
= 15V, V
OUT
= 2V
V
IN+
= 0V, V
IN-
= 1V, +V
S
= 15V, V
OUT
= 2V
V
IN+
= 0V, V
IN-
= 1V, +V
S
= 15V, V
OUT
= 0.2V
Min
20
20
10
5
12
Typ
40
15
50
40
Max
Units
mA
LM358, LM324
Low Power, 3V to 36V, Single/Dual/Quad Amplifiers
mA
μA
60
mA
I
SINK
I
SC
Notes:
Output Current, Sinking
(1)
Short Circuit Output Current
(1)
+V
S
= 15V
1. 100% tested at 25°C. (Limits over the full temperature range are guaranteed by design.)
2. The input common mode voltage of either input signal voltage should be kept > 0.3V at 25°C. The upper end of the common-mode voltage range is +V
S
- 1.5V at
25°C, but either or both inputs can go to +36V without damages, independent of the magnitude of V
S
.
Rev 1A
©2011 CADEKA Microcircuits LLC
www.cadeka.com