Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper de-
vice function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect the
operating conditions noted on the tables and plots.
Parameter
Min
0
Max
Unit
Supply Voltage
40
40
V
V
Differential Input Voltage
Input Voltage
-0.3
40
V
Power Dissipation (T = 25°C) - SOIC-8
550
800
mW
mW
A
Power Dissipation (T = 25°C) - SOIC-14
A
Reliability Information
Parameter
Min
Typ
Max
Unit
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Package Thermal Resistance
SOIC-8
150
150
260
°C
°C
°C
-65
100
88
°C/W
°C/W
SOIC-14
Notes:
Package thermal resistance (q ), JDEC standard, multi-layer test boards, still air.
JA
Recommended Operating Conditions
Parameter
Min
Typ
Max
Unit
Operating Temperature Range
Supply Voltage Range
-40
+85
°C
V
3 (±1.5)
36 (±18)
©2011 CADEKA Microcircuits LLC