Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper device
function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect the
operating conditions noted on the tables and plots.
CDK2307
Dual, 20/40/65/80MSPS, 12/13-bit Analog-to-Digital Converters
Parameter
AVDD, AVSS
DVDD, DVSS
AVSS, DVSSCLK, DVSS, OVSS
OVDD, OVSS
CKP, CKN, DVSSCLK
Analog inputs and outpts (IPx, INx, AVSS)
Digital inputs
Digital outputs
Min
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
Max
+2.3
+2.3
+0.3
+3.9
+3.9
+2.3
+3.9
+3.9
Unit
V
V
V
V
V
V
V
V
Reliability Information
Parameter
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Min
-40
-60
J-STD-020
Typ
Max
85
+150
Unit
°C
°C
°C
ESD Protection
Product
Human Body Model (HBM)
QFN-64
TBD
TQFP-64
2kV
Recommended Operating Conditions
Parameter
Operating Temperature Range
Min
-40
Typ
Max
+85
Unit
°C
Rev 2A
©2009 CADEKA Microcircuits LLC
www.cadeka.com
4