欢迎访问ic37.com |
会员登录 免费注册
发布采购

BMA253 参数 Datasheet PDF下载

BMA253图片预览
型号: BMA253
PDF下载: 下载PDF文件 查看货源
内容描述: [3轴 12bit 加速度传感器]
分类和应用: 传感器
文件页数/大小: 119 页 / 2014 K
品牌: BOSCH [ Bosch Sensortec GmbH ]
 浏览型号BMA253的Datasheet PDF文件第35页浏览型号BMA253的Datasheet PDF文件第36页浏览型号BMA253的Datasheet PDF文件第37页浏览型号BMA253的Datasheet PDF文件第38页浏览型号BMA253的Datasheet PDF文件第40页浏览型号BMA253的Datasheet PDF文件第41页浏览型号BMA253的Datasheet PDF文件第42页浏览型号BMA253的Datasheet PDF文件第43页  
BMA253  
Data sheet  
Page 39  
4.7.8 Flat detection  
The flat detection feature gives information about the orientation of the devices´ z-axis relative  
to the g-vector, i. e. it recognizes whether the device is in a flat position or not.  
The flat angle is adjustable by (0x2E) flat_theta from 0° to 44.8°. The flat angle can be set  
according to following formula:  
1
8
  atan  
flat_theta  
A hysteresis of the flat detection can be enabled by (0x2F) flat_hy bits. In this case the flat  
position is set if the angle drops below following threshold:  
1
8
flat _ hy  
flat _ hy  
hyst,ll atan  
flat_theta1  
1024  
16  
The flat position is reset if the angle exceeds the following threshold:  
1
8
flat _ hy  
flat _ hy  
hyst,ul atan  
flat_theta1  
1024  
16  
The flat interrupt is enabled (disabled) by writing ´1´ (´0´) to bit (0x16) flat_en. The flat value is  
stored in the (0x0C) flat bit if the interrupt is enabled. This value is ´1´ if the device is in the flat  
position, it is ´0´ otherwise. The flat interrupt is generated if the flat value has changed and the  
new value is stable for at least the time given by the (0x2F) flat_hold_time bits. A flat interrupt  
may be also generated if the flat interrupt is enabled. The actual status of the interrupt is stored  
in the (0x09) flat_int bit. The flat orientation of the sensor can always be determined from  
reading the (0x0C) flat bit after interrupt generation. If unlatched interrupt mode is used, the  
(0x09) flat_int value and hence the interrupt is automatically cleared after one sample period. If  
temporary or latched interrupt mode is used, the (0x09) flat_int value is kept fixed until the latch  
time expires or the interrupt is reset.  
The meaning of the (0x2F) flat_hold_time bits can be seen from Table 18.  
Table 18: Meaning of flat_hold_time  
(0x2F)  
Time  
flat_hold_time  
00b  
01b  
10b  
11b  
0
512 ms  
1024 ms  
2048 ms  
BST-BMA253-DS000-01 | Revision 1.0 | August 2015  
Bosch Sensortec  
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to  
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.  
Note: Specifications within this document are subject to change without notice.  
 
 复制成功!