PIN DESCRIPTIONS
Pin
1
2
3
4,5
6
7,8
9
10
11
12
Symbol
VDD
NC
NC
V1A,V1B
V1N
V2N,V2P
NC
VREF
GND
SCF
Single Phase Energy Meter IC
with Integrated Oscillator
DESCRIPTIONS
Power Supply (+5V). Provides the supply voltage for the circuitry. It should be
maintained at 5 V±5% for specified operation.
No connect.
No connect
Inputs for Current Channel. These inputs are fully differential voltage inputs with a
maximum signal level of
±660
mV with respect to pin6 (V1N) for specified
operation.
Negative Input Pin for Differential Voltage Inputs V1A and V1B.
Negative and Positive Inputs for Voltage Channel. These inputs provide a fully
differential input pair. The maximum differential input voltage is
±660
mV for
specified operation.
No connect
On-Chip Voltage Reference. The on-chip reference has a nominal value of 2.5V
±
8% and a typical temperature coefficient of 30ppm/℃. An external reference source
may also be connected at this pin.
Ground Reference. Provides the ground reference for the circuitry.
Calibration Frequency Select. This logic input is used to select the frequency on the
calibration output CF.
Output Frequency Select. These logic inputs are used to select one of four possible
frequencies for the digital-to-frequency conversion. This offers the designer greater
flexibility when designing the energy meter.
Gain Select. These logic inputs are used to select one of four possible gains for current
channel. The possible gains are 1, 2, 8, and 16.
No connect
No connect
Fault Indication. Logic high indicates fault condition. Fault is defined as a condition
under which the signals on V1A and V1B differ by more than 12.5%. The logic output
will be reset to zero when fault condition is no longer detected.
Negative Indication. Logic high indicates negative power, i.e., when the phase angle
between the voltage and current signals is greater that 90°. This output is not latched
and will be reset when positive power is once again detected.
No connect
Calibration Frequency. The CF logic output gives instantaneous real power
information. This output is intended to use for calibration purposes.
Low-Frequency. F1 and F2 supply average real power information. The logic outputs
can be used to directly drive electromechanical counters and 2-phase stepper motors.
13,14
S1,S0
15,16
17
18
19
G1,G0
NC
NC
FAULT
20
21
22
23,24
REVP
NC
CF
F1,F2