The transfer function through the complete instrumentation  
amplifier and voltage-to-current converter is:  
APPLICATION INFORMATION  
Figure 1 shows the basic connection diagram for the XTR105.  
The loop power supply, VPS, provides power for all cir-  
cuitry. Output loop current is measured as a voltage across  
the series load resistor, RL.  
IO = 4mA + VIN • (40/RG)  
(VIN in volts, RG in ohms)  
where VIN is the differential input voltage. As evident from  
the transfer function, if no RG is used the gain is zero and the  
output is simply the XTR105’s zero current. The value of RG  
varies slightly for two-wire RTD and three-wire RTD con-  
nections with linearization. RG can be calculated from the  
equations given in Figure 1 (two-wire RTD connection) and  
Table I (three-wire RTD connection).  
Two matched 0.8mA current sources drive the RTD and  
zero-setting resistor, RZ. The instrumentation amplifier in-  
put of the XTR105 measures the voltage difference between  
the RTD and RZ. The value of RZ is chosen to be equal to  
the resistance of the RTD at the low-scale (minimum)  
measurement temperature. RZ can be adjusted to achieve  
4mA output at the minimum measurement temperature to  
correct for input offset voltage and reference current mis-  
match of the XTR105.  
The IRET pin is the return path for all current from the current  
sources and VREG. The IRET pin allows any current used in  
external circuitry to be sensed by the XTR105 and to be  
included in the output current without causing an error.  
R
CM provides an additional voltage drop to bias the inputs of  
the XTR105 within their common-mode input range. RCM  
should be bypassed with a 0.01µF capacitor to minimize  
common-mode noise. Resistor RG sets the gain of the instru-  
mentation amplifier according to the desired temperature  
range. RLIN1 provides second-order linearization correction  
to the RTD, typically achieving a 40:1 improvement in  
linearity. An additional resistor is required for three-wire  
RTD connections, see Figure 3.  
The VREG pin provides an on-chip voltage source of approxi-  
mately 5.1V and is suitable for powering external input  
circuitry (refer to Figure 6). It is a moderately accurate  
voltage reference—it is not the same reference used to set  
the 800µA current references. VREG is capable of sourcing  
approximately 1mA of current. Exceeding 1mA may affect  
the 4mA zero output.  
IR = 0.8mA  
IR = 0.8mA  
Possible choices for Q1 (see text).  
TYPE  
PACKAGE  
2N4922  
TIP29C  
TIP31C  
TO-225  
TO-220  
TO-220  
12  
1
IR1  
7.5V to 36V  
VLIN  
14  
13  
11  
VI+N  
IR2  
10  
V+  
VREG  
IO  
4
RG  
4-20 mA  
9
8
R(G2)  
B
E
0.01µF  
Q1  
XTR105  
VO  
+
3
2
RG  
VIN  
(3)  
RLIN1  
RL  
VPS  
IO  
7
IRET  
(1)  
6
40  
RG  
RTD  
RZ  
IO = 4mA + VIN • (  
)
NOTES: (1) RZ = RTD resistance at minimum measured temperature.  
2R1(R2 +RZ) – 4(R2RZ)  
RCM = 1kΩ  
(2)  
RG  
=
R2 – R1  
RLIN(R2 – R1)  
(3)  
0.01µF  
RLIN1 =  
2(2R1 – R2 – RZ)  
where R1 = RTD Resistance at (TMIN + TMAX)/2  
R
2 = RTD Resistance at TMAX  
RLIN = 1k(Internal)  
FIGURE 1. Basic Two-Wire RTD Temperature Measurement Circuit with Linearization.  
®