欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADS7835EB 参数 Datasheet PDF下载

ADS7835EB图片预览
型号: ADS7835EB
PDF下载: 下载PDF文件 查看货源
内容描述: 12位,高速,低功耗采样模拟数字转换器 [12-Bit, High-Speed, Low Power Sampling ANALOG-TO-DIGITAL CONVERTER]
分类和应用: 转换器光电二极管
文件页数/大小: 13 页 / 171 K
品牌: BB [ BURR-BROWN CORPORATION ]
 浏览型号ADS7835EB的Datasheet PDF文件第5页浏览型号ADS7835EB的Datasheet PDF文件第6页浏览型号ADS7835EB的Datasheet PDF文件第7页浏览型号ADS7835EB的Datasheet PDF文件第8页浏览型号ADS7835EB的Datasheet PDF文件第10页浏览型号ADS7835EB的Datasheet PDF文件第11页浏览型号ADS7835EB的Datasheet PDF文件第12页浏览型号ADS7835EB的Datasheet PDF文件第13页  
clock cycle is the first of the conversion.)  
tween conversions.  
In addition, if CONV is completely asynchronous to CLK  
and CLK is continuous, there is the possibility that CLK will  
transition just prior to CONV going LOW. If this occurs  
faster than the 10ns indicated by tCKCH, there is a chance that  
some digital feedthrough may be coupled onto the hold  
capacitor. This could cause a small offset error for that  
particular conversion.  
Figure 4 shows the typical method for placing the A/D into  
the power-down mode. If CONV is kept LOW during the  
conversion and is LOW at the start of the 13th clock cycle,  
the device enters the power-down mode. It remains in this  
mode until the rising edge of CONV. Note that CONV must  
be HIGH for at least tACQ in order to sample the signal  
properly as well as to power-up the internal nodes.  
Thus, there are two basic ways to operate the ADS7835.  
CONV can be synchronous to CLK and CLK can be con-  
tinuous. This would be the typical situation when interfacing  
the converter to a digital signal processor. The second  
method involves having CONV asynchronous to CLK and  
gating the operation of CLK (a non-continuous clock). This  
method would be more typical of an SPI-like interface on a  
microcontroller. This method would also allow CONV to be  
generated by a trigger circuit and to initiate (after some  
delay) the start of CLK. These two methods are covered  
under the DSP Interfacing and SPI Interfacing sections of  
this data sheet.  
There are two different methods for clocking the ADS7835.  
The first involves scaling the CLK input in relation to the  
conversion rate. For example, an 8MHz input clock and the  
timing shown in Figure 3 results in a 500kHz conversion  
rate. Likewise, a 1.6MHz clock would result in a 100kHz  
conversion rate. The second method involves keeping the  
clock input as close to the maximum clock rate as possible  
and starting conversions as needed. This timing is similar to  
that shown in Figure 4. As an example, a 50kHz conversion  
rate would require 160 clock periods per conversion instead  
of the 16 clock periods used at 500kHz.  
The main distinction between the two is the amount of time  
that the ADS7835 remains in power-down. In the first mode,  
the converter only remains in power-down for a small  
number of clock periods (depending on how many clock  
periods there are per each conversion). As the conversion  
rate scales, the converter always spends the same percentage  
of time in power-down. Since less power is drawn by the  
digital logic, there is a small decrease in power consump-  
tion, but it is very slight. This effect can be seen in the  
POWER-DOWN TIMING  
The conversion timing shown in Figure 3 does not result in  
the ADS7835 going into the power-down mode. If the  
conversion rate of the device is high (approaching 500kHz),  
there is very little power that can be saved by using the  
power-down mode. However, since the power-down mode  
incurs no conversion penalty (the very first conversion is  
valid) at lower sample rates, significant power can be saved  
by allowing the device to go into power-down mode be-  
tCVL  
tCVCK  
CONV  
tCKCS  
tCKCH  
14  
15  
16  
1
2
3
4
11  
12  
13  
14  
15  
16  
1
CLK  
(1)  
tCKDE  
tCKDD  
D11  
(MSB)  
D0  
(LSB)  
DATA  
D10  
D9  
D2  
D1  
tACQ  
tCVHD  
tCKSP  
SAMPLE/HOLD  
MODE  
SAMPLE  
HOLD  
tCONV  
SAMPLE  
HOLD  
(2)  
INTERNAL  
CONVERSION  
STATE  
(
3)  
IDLE  
IDLE  
CONVERSION IN PROGRESS  
NOTES: (1) Clock periods 14 and 15 are shown for clarity, but are not required for proper operation of the ADS7835, provided that the  
minimum tACQ time is met. The CLK input may remain HIGH or LOW during this period. (2) The transition from sample mode to hold  
mode occurs on the falling edge of CONV. This transition is not dependent on CLK. (3) The device remains fully powered when  
operated as shown. If the sample time is longer than 3 clock periods, power consumption can be reduced by allowing the device to  
enter a power-down mode. See the Power-Down Timing section for more information.  
FIGURE 3. Basic Conversion Timing.  
®
9
ADS7835