欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADC601SG 参数 Datasheet PDF下载

ADC601SG图片预览
型号: ADC601SG
PDF下载: 下载PDF文件 查看货源
内容描述: [A/D Converter, 12-Bit, 1 Func, Hybrid, CDIP32,]
分类和应用: 转换器
文件页数/大小: 4 页 / 43 K
品牌: BB [ BURR-BROWN CORPORATION ]
 浏览型号ADC601SG的Datasheet PDF文件第1页浏览型号ADC601SG的Datasheet PDF文件第2页浏览型号ADC601SG的Datasheet PDF文件第3页  
PIN CONFIGURATION  
(MSB) Bit 1  
1
2
32 Common (Analog)  
31 NC (1)  
Bit 2  
Bipolar  
Bit 3  
3
30 –VCC (–15V) Analog  
29 Bipolar Offset Current  
28 Common (Analog)  
27 Ground Sense  
26 Comparator Input  
25 10V Input  
Reference  
Bit 4  
4
CMOS  
Bit 5  
Bit 6  
5
6
+V DD (+5V) Digital  
Common (Digital)  
Serial Out  
Status  
7
1k  
2kΩ  
8
9
24 20V Input  
10  
11  
12  
13  
14  
15  
16  
23 VCC (–15V) Analog  
22 +VDD (+5V) Digital(2)  
21 Common (Digital)  
20 +VCC (+15V) Analog  
19 Clock Rate Control  
18 Convert Command  
17 Clock Out  
Bit 7  
Bit 8  
+
Bit 9  
545Ω  
Bit 10  
Bit 11  
Bit 12  
Clock  
(1) NC = No internal connection. Any voltage may be connected to pin 31, however.  
(2) Pin 22 must be very cleanly decoupled to keep digital noise out of the analog circuits.  
PIN DEFINITIONS  
PIN NUMBER  
DESIGNATION  
DESCRIPTION  
1-6 and 11-16  
Bit 1 to Bit 12  
Serial Out  
Status  
12-bit parallel output data capable of sinking 3.2mA.  
9
12-bit serial data output synchronized with the negative edge of each appropriate clock cycle.  
10  
Conversionstatusstrobeishighduringdataconversion;lowwhenparalleldataisvalid. Negativeedgemay  
be used to latch parallel data, however, appropriate latch set-up time must be provided. Refer to tBBL in the  
ADC601 timing diagram.  
17  
18  
Clock Out  
Negative edge indicates when serial data is valid. After convert command goes high, fist cycle clocks bit 1  
(MSB). The clock continues to run when convert command is high and resets low with convert command.  
Convert Command  
High transition starts conversion; and should remain high during conversion. Low will reset clock and SAR  
logic.  
19  
24  
25  
26  
27  
Clock Rate Control  
20V Input  
Maybeusedtoincreaseclockspeed,byincreasingthepositiveportionoftheclock.Highisnormaloperation.  
20V input range allows ±10Vp-p analog input signal. Short to ground when not used.  
10V input range allows 0 to –10Vp-p or ±5Vp-p input range.  
10V Input  
Comparator In  
Ground Sense  
Only used in bipolar mode when it is connected to bipolar offset pin through short lead with low resistance.  
Ground Sense pin. (See text for use).  
29  
Bipolar Offset Current  
Bipolar offset current short to comparator In through very short lead with very low resistance for bipolar  
operation. Short to ground for unipolar operation.  
®
ADC601  
4