WORLD-BEAM QS18U Ultrasonic Sensors
Specifications
Sensing Range
Repeatability
50 to 500 mm (2 to 20 inches)
0.7 mm
Supply Voltage
Minimum Window Size
12 to 30 V dc (10% maximum ripple); 25 mA max (exclusive of load)
5 mm
Ultrasonic Frequency
Hysteresis
300 kHz, rep. rate 7.5 ms
1.4 mm
Supply Protection Circuitry
Adjustments
Protected against reverse polarity and transient voltages
Sensing Window Limits: TEACH-mode programming of near and far
window limits may be set using the push button or remotely via TEACH
input
Output Configuration
SPST solid-state switch conducts when target is sensed within sensing
window; one NPN (current sinking) or one PNP (current sourcing),
depending on model.
Indicators
Range Indicator (Red/Green) and Teach/Output Indicator
(Amber/Red)
Range Indicator: Green - Target is within sensing range; Red - Target
is outside sensing range; OFF - Sensing Power is OFF
Teach/Output Indicator: Amber - Target is within taught limits; OFF -
Target is outside taught window limits; Red - Sensor is in TEACH mode
Output Protection
Protected against short-circuit conditions
Output Rating
Rating: 100 mA maximum load; see Application Note 1
Off-state leakage current: less than 10 µA (sourcing); less than 200
µA (sinking); see Application Note 2
ON-state saturation voltage: NPN: less than 1.6 V @ 100 mA; PNP:
less than 3.0 V @ 100 mA
Construction
ABS housing, TPE Push Button, ABS Push Button housing,
Polycarbonate lightpipes
Connections
Output Response
2 m (6.5 ft) or 9 m (30 ft) 4-conductor PVC jacketed attached cable, or
4-pin Euro-style integral QD (Q8), or 4-pin Pico-style integral QD (Q7),
or 4-pin Euro-style 150 mm (6 in) pigtail QD (Q5), or 4-pin Pico-style
150 mm (6 in) pigtail QD (Q)
15 milliseconds
Delay at Power Up
300 milliseconds
Temperature Warmup Drift
See Temperature Compensation on page 2
Temperature Effect
Non-encapsulated models: ± 0.05% per °C from –20 to 50 °C, ± 0.1%
per °C from 50 to 60 °C
Encapsulated models: ± 0.05% per °C from 0 to 60 °C, ± 0.1% per °C
from –20 to 0 °C
Application Notes
Required Overcurrent Protection
1. If supply voltage is > 24 V dc, derate maximum output current 5
mA/°C above 50 °C.
2. NPN off-state leakage current is < 200 µA for load resistances > 3
kΩ or optically isolated loads. For load current of 100 mA, leakage is <
1% of load current.
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
3. Objects passing inside the specified near limit may produce a false
response.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to http://
www.bannerengineering.com.
Environmental Rating
Leakproof design, rated NEMA 6P; IEC IP67 or IP68 depending on
model; UL Type 1
Operating Conditions
Temperature: −20 °C to 60 °C (−4 °F to 140 °F)
Relative Humidity: 100% (non-condensing)
Supply Wiring
Required Overcurrent Protection
Vibration and Mechanical Shock
20
22
24
26
28
30
5.0 Amps
3.0 Amps
2.0 Amps
1.0 Amps
0.8 Amps
0.5 Amps
All models meet Mil. Std. 202F requirements method 201A (vibration:
10 to 60 Hz max., double amplitude 0.06", maximum acceleration
10G). Also meets IEC 947-5-2 requirements: 30G 11 ms duration, half
sine wave.
Certifications
6
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 119287 Rev. J