Designed and
Manufactured
in Germany
Ordering Code
Model
Option 1
[Stability]
STD, MS, HS
Option 2
[Phase noise]
Table 1
Revision
Frequency [MHz]
AXRB9000
Rev.3
10.000
Example: AXRB9000-HS-ULN_Rev.3 – 10.000 MHz
Note: Option 2 = “ULN” only available for Options 1 “MS” and “HS”
Phase Noise – Option 2:
10 MHz
LN
Offset
Unit
ULN
-105
-138
-155
-163
-170
1 Hz
10 Hz
-100
-130
-145
-155
-155
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
100 Hz
1 kHz
≥10 kHz
Table 1
Extension of AXRB9000 with optional distribution amplifier AXDA9000
Handling & Testing
Parameter
Procedure / Test condition
Sinusoidal vibration
Random vibration
Mechanical shock
Handling and Testing
max. 0.15 mm <10 Hz, 1 g at 10~2000 Hz
max. 0.001 g²/Hz, 10~2000 Hz
max. 10 g, 6 ms half sine
Careful handling. Avoid excessive air flow,
vibration and shock during operation.
VDE 0701-0702 Tested
RoHS-Compliant
” Yes 5 No
” Yes 5 No
GmbH & Co. KG
AXRB9000 Rev.3
Drawing D0
Page 3(5)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: info@axtal.com
Roemerring 9
D-74821 Mosbach
Germany