MIL-C-123
HOW TO ORDER
Military Type Designation: Capacitors, Fixed, Ceramic
Dielectric, (Temperature Stable and General Purpose),
High Reliability
Part Number Example
M123
A
01
BX
B
103
K
C
Mil-Spec Number
Modification Spec.
Slash Sheet Number
Characteristic Temperature
Voltage
Capacitance Code
Capacitance Tolerance
Termination
Part Number Codes
Voltage-Temperature Limits:
Rated Voltage:
Capacitance Tolerance:
Capacitance change with reference to 25°C
over temperature range -55°C to +125°C
Cap. Tolerance
Rated Voltage
Volts, DC
Symbol
±
Symbol
C
D
E
J
0.25pF
0.5 pF
1%
B
C
50
100
Symbol
Without Voltage
With Rated DC Voltage
BP
BX
0 ± 30 ppm/°C
+15, -15 percent
0 ± 30 ppm/°C
+15, -25 percent
5%
K
10%
Termination:
Lead Capacitors
Termination Style
Symbol
C
W
Copper, solder coated (type C-4 or C-5 of MIL-STD-1276)
Copper clad steel, solder coated, 60 micro inches minimum.
CROSS REFERENCE MIL-SPEC TEST REQUIREMENTS
TEST DESCRIPTION
MIL-C-123
MIL-C-39014
MIL-C-20
MIL-C-55681
NDT
100% Ultrasonic Scan or
Neutron-Radiography
No
No
No
No
No
No
(Non-Destructive Test)
Pre-Cap Visual
(Pre-Encapsulation
Visual Examination)
100%
No
No
No
No
No
No
D.P.A.
Lot by Lot—Pre-Termination
Lot by Lot—Finished Product
(Destructive Physical Analysis)
Pre-Cap
Terminal Strength
(Pre-Encapsulation Pull Test)
Lot by Lot
Life Test
(Lot by Lot)
Lot by Lot—1000 Hours
Lot by Lot
No
No
No
No
No
No
No
No
No
Low Voltage
Humidity
Thermal Shock
100 Cycles
Lot by Lot
63