MIL-C-20/Axial Leads
HOW TO ORDER
Military Type Designation:
Established Reliability = CCR75, CCR76, CCR77, CCR78, CCR79
Non-Established Reliability = CC75, CC76, CC77, CC78, CC79
Part Number Example
CCR76
CG
102
J
R
Style
Temperature Characteristic
Capacitance Code
Capacitance Tolerance
Military Failure Rate
1.25
MIN.
D
MIL Part No. Codes
L
L.D.
Style: CC = Identifies temperature compensating,
ceramic dielectric, fixed capacitors.
R = Identifies Established Reliability parts.
76 = Numbers identify shape and dimension.
Temperature Characteristic:
Permissible capacitance change from capacitance at +25°C in ppm/°C
SIZE SPECIFICATIONS
Temp.
Characteristic
CJ
Dimensions: Millimeters (Inches)
CX
CK
CH
CG
Per MIL
+125°C
1/
±250 ppm/°C ±120 ppm/°C
±60 ppm/°C ±30 ppm/°C
Case Size
Spec
+246.25
-326.25
+116.25
-166.25
+55.00
-91.25
+27.50
-53.75
-55°C 2/
1/
Length
(L)
Diameter
Lead Diameter
(L.D.)
MIL-C-20
(D)
1/ Not practically measurable.
CCR75
CC75
4.07±.25
(.160±.010)
2.29±.25
(.090±.010)
.48±.05
(.019±.002)
Capacitance Code:
First two digits are the significant figures of capacitance.
Third digit indicates the additional number of zeros. For
example, order 1,000 pF as 102. (For values below 10 pF,
use “R” in place of decimal point, e.g., 1R8 - 1.8pF).
CCR76
CC76
6.35±.25
2.29±.25
.48±.05
(.250±.010)
(.090±.010)
(.019±.002)
CCR77
CC77
9.91±.25
(.390±.010)
3.56±.25
(.140±.010)
.63±.05
(.025±.002)
Capacitance Tolerance:
C = ±0.25 pF, D = ±0.5 pF, F = ±1%,
G = ±2%, J = ±5%, K = ±10%
CCR78
CC78
12.7±.51
(.500±.020)
6.35±.38
(.250±.015)
.63±.05
(.025±.002)
Military Failure Rate:
CCR79
CC79
17.53±.51
(.690±.020)
8.89±.51
(.350±.020)
.63±.05
(.025±.002)
M = 1% per 1000 hours, P = 0.1% per 1000 hours,
R = 0.01% per 1000 hours, S = 0.001% per 1000 hours.
PACKAGING REQUIREMENTS
Packaging:
Tape & Reel
Bulk
CCR75/CC75, CCR76/CC76
CCR77/CC77
5000 pcs/reel
3000 pcs/reel
950 pcs/reel
650 pcs/reel
CCR75/CC75, CCR76/CC76, CCR77/CC77,
CCR78/CC78, CCR79/CC79
100 pcs/bag
50 pcs/bag
CCR78/CC78
CCR79/CC79