 浏览型号08055A100CAT2A的Datasheet PDF文件第37页浏览型号08055A100CAT2A的Datasheet PDF文件第38页浏览型号08055A100CAT2A的Datasheet PDF文件第39页浏览型号08055A100CAT2A的Datasheet PDF文件第40页浏览型号08055A100CAT2A的Datasheet PDF文件第42页浏览型号08055A100CAT2A的Datasheet PDF文件第43页浏览型号08055A100CAT2A的Datasheet PDF文件第44页浏览型号08055A100CAT2A的Datasheet PDF文件第45页  
General Description  
di  
dt  
is determined by dividing the rated voltage by IR (Ohm’s  
Law).  
The  
seen in current microprocessors can be as high as  
0.3 A/ns, and up to 10A/ns. At 0.3 A/ns, 100pH of parasitic  
inductance can cause a voltage spike of 30mV. While this  
does not sound very drastic, with the Vcc for microproces-  
sors decreasing at the current rate, this can be a fairly large  
percentage.  
Dielectric Strength – Dielectric Strength is an expression  
of the ability of a material to withstand an electrical stress.  
Although dielectric strength is ordinarily expressed in volts, it  
is actually dependent on the thickness of the dielectric and  
thus is also more generically a function of volts/mil.  
Another important, often overlooked, reason for knowing  
the parasitic inductance is the calculation of the resonant  
frequency. This can be important for high frequency, by-  
pass capacitors, as the resonant point will give the most  
signal attenuation. The resonant frequency is calculated  
from the simple equation:  
Dielectric Absorption – A capacitor does not discharge  
instantaneously upon application of a short circuit, but  
drains gradually after the capacitance proper has been dis-  
charged. It is common practice to measure the dielectric  
absorption by determining the “reappearing voltage” which  
appears across a capacitor at some point in time after it has  
been fully discharged under short circuit conditions.  
fres =  
1
ͱ
2LC  
Corona – Corona is the ionization of air or other vapors  
which causes them to conduct current. It is especially  
prevalent in high voltage units but can occur with low voltages  
as well where high voltage gradients occur. The energy  
discharged degrades the performance of the capacitor and  
can in time cause catastrophic failures.  
Insulation Resistance – Insulation Resistance is the resis-  
tance measured across the terminals of a capacitor and  
consists principally of the parallel resistance RP shown in  
the equivalent circuit. As capacitance values and hence the  
area of dielectric increases, the I.R. decreases and hence  
the product (C x IR or RC) is often specified in ohm farads  
or more commonly megohm-microfarads. Leakage current  
40  