IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
(HCPL-06xx Option 060 Only)
Description
Symbol
Characteristic
Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V rms
I-IV
I-III
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
Climatic Classification
I-III
55/85/21
2
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
V
567
Vpeak
Vpeak
IORM
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
VPR
VPR
1063
851
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and Sample Test,
tm = 60 sec, Partial Discharge < 5 pC
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage, tini = 10 sec)
VIOTM
6000
Vpeak
Safety Limiting Values
(Maximum values allowed in the event of a failure)
Case Temperature
Input Current**
TS
IS,INPUT
PS,OUTPUT
150
150
600
°C
mA
mW
Output Power**
Insulation Resistance at TS, V = 500 V
RS
≥109
IO
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
9