IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCPL-26xx; 46xx; 6N13x Option 060 Only)
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
I-IV
I-IV
40/85/21
2
V
630
Vpeak
Vpeak
IORM
VPR
VPR
1181
1008
6000
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and sample test, tm = 10 sec,
Partial Discharge < 5 pC
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage, tini = 60 sec)
Safety Limiting Values (Maximum values allowed in the event of a failure)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
VIOTM
Vpeak
TS
IS,INPUT
PS,OUTPUT
175
230
600
≥109
°C
mA
mW
RS
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCNW137/2601/2611 Only)
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
I-IV
I-III
40/85/21
2
V
1414
Vpeak
Vpeak
IORM
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and sample test, tm = 10 sec,
Partial Discharge < 5 pC
VPR
VPR
2651
2262
8000
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage, tini = 60 sec)
VIOTM
Vpeak
Safety Limiting Values (Maximum values allowed in the event of a failure)
Case Temperature
Input Current
Output Power
TS
IS,INPUT
PS,OUTPUT
150
400
700
°C
mA
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.