Insulation and Safety Related Specifications
8-pin DIP
(300 Mil)
Value
Widebody
(400 Mil)
Value
SO-8
Value
Parameter
Symbol
Unit
Conditions
Minimum External
Air Gap
(External Clearance)
L(101)
7.1
4.9
9.6
10.0
1.0
mm
Measured from input terminals
to output terminals, shortest
distance through air.
Minimum External
Tracking
(External Creepage)
L(102)
7.4
4.8
mm
mm
Measured from input terminals
to output terminals, shortest
distance path along body.
Minimum Internal
Plastic Gap
(Internal Clearance)
0.08
0.08
Through insulation distance,
conductor to conductor, usually
the direct distance between the
photoemitter and photodetector
inside the optocoupler cavity.
Minimum Internal
Tracking
(Internal Creepage)
NA
NA
4.0
mm
V
Measured from input terminals
to output terminals, along
internal cavity.
Tracking Resistance
(Comparative Tracking Index)
CTI
200
IIIa
200
IIIa
200
IIIa
DIN IEC 112/VDE 0303 Part 1
Isolation Group
Material Group
(DIN VDE 0110, 1/89, Table 1)
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCPL-06xx Option 060 Only)
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 Vrms
I-IV
I-IV
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic Classification
I-III
40/85/21
2
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
V
567
Vpeak
Vpeak
IORM
Input-to-Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
VPR
VPR
1063
907
Input-to-Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial Discharge < 5 pC
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage, tini = 60 sec)
VIOTM
6000
Vpeak
Safety Limiting Values (Maximum values allowed in the event of a failure)
Case Temperature
Input Current**
Output Power**
TS
IS,INPUT
PS,OUTPUT
150
150
600
°C
mA
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.