欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-0601-500E 参数 Datasheet PDF下载

HCPL-0601-500E图片预览
型号: HCPL-0601-500E
PDF下载: 下载PDF文件 查看货源
内容描述: 高CMR ,高速TTL兼容光电耦合器 [High CMR, High Speed TTL Compatible Optocouplers]
分类和应用: 光电输出元件
文件页数/大小: 21 页 / 431 K
品牌: AVAGO [ AVAGO TECHNOLOGIES LIMITED ]
 浏览型号HCPL-0601-500E的Datasheet PDF文件第4页浏览型号HCPL-0601-500E的Datasheet PDF文件第5页浏览型号HCPL-0601-500E的Datasheet PDF文件第6页浏览型号HCPL-0601-500E的Datasheet PDF文件第7页浏览型号HCPL-0601-500E的Datasheet PDF文件第9页浏览型号HCPL-0601-500E的Datasheet PDF文件第10页浏览型号HCPL-0601-500E的Datasheet PDF文件第11页浏览型号HCPL-0601-500E的Datasheet PDF文件第12页  
Insulation and Safety Related Specifications  
8-pin DIP  
(300 Mil)  
Value  
Widebody  
(400 Mil)  
Value  
SO-8  
Value  
Parameter  
Symbol  
Unit  
Conditions  
Minimum External  
Air Gap  
(External Clearance)  
L(101)  
7.1  
4.9  
9.6  
10.0  
1.0  
mm  
Measured from input terminals  
to output terminals, shortest  
distance through air.  
Minimum External  
Tracking  
(External Creepage)  
L(102)  
7.4  
4.8  
mm  
mm  
Measured from input terminals  
to output terminals, shortest  
distance path along body.  
Minimum Internal  
Plastic Gap  
(Internal Clearance)  
0.08  
0.08  
Through insulation distance,  
conductor to conductor, usually  
the direct distance between the  
photoemitter and photodetector  
inside the optocoupler cavity.  
Minimum Internal  
Tracking  
(Internal Creepage)  
NA  
NA  
4.0  
mm  
V
Measured from input terminals  
to output terminals, along  
internal cavity.  
Tracking Resistance  
(Comparative Tracking Index)  
CTI  
200  
IIIa  
200  
IIIa  
200  
IIIa  
DIN IEC 112/VDE 0303 Part 1  
Isolation Group  
Material Group  
(DIN VDE 0110, 1/89, Table 1)  
Option 300 - surface mount classification is Class A in accordance with CECC 00802.  
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*  
(HCPL-06xx Option 060 Only)  
Description  
Symbol  
Characteristic  
Unit  
Installation classification per DIN VDE 0110, Table 1  
for rated mains voltage ≤ 150 Vrms  
I-IV  
I-IV  
for rated mains voltage ≤ 300 Vrms  
for rated mains voltage ≤ 600 Vrms  
Climatic Classification  
I-III  
40/85/21  
2
Pollution Degree (DIN VDE 0110/39)  
Maximum Working Insulation Voltage  
V
567  
Vpeak  
Vpeak  
IORM  
Input-to-Output Test Voltage, Method b*  
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,  
Partial Discharge < 5 pC  
VPR  
VPR  
1063  
907  
Input-to-Output Test Voltage, Method a*  
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,  
Partial Discharge < 5 pC  
Vpeak  
Highest Allowable Overvoltage  
(Transient Overvoltage, tini = 60 sec)  
VIOTM  
6000  
Vpeak  
Safety Limiting Values (Maximum values allowed in the event of a failure)  
Case Temperature  
Input Current**  
Output Power**  
TS  
IS,INPUT  
PS,OUTPUT  
150  
150  
600  
°C  
mA  
mW  
Insulation Resistance at TS, VIO = 500 V  
RS  
≥109  
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a  
detailed description.  
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.  
8