 浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第253页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第254页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第255页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第256页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第258页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第259页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第260页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第261页  
ATmega8U2/16U2/32U2  
25.7.9  
Programming the Fuse High Bits  
The algorithm for programming the Fuse High bits is as follows (refer to “Programming the  
Flash” on page 253 for details on Command and Data loading):  
1. A: Load Command “0100 0000”.  
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.  
3. Set BS2, BS1 to “01”. This selects high data byte.  
4. Give WR a negative pulse and wait for RDY/BSY to go high.  
5. Set BS2, BS1 to “00”. This selects low data byte.  
25.7.10 Programming the Extended Fuse Bits  
The algorithm for programming the Extended Fuse bits is as follows (refer to “Programming the  
Flash” on page 253 for details on Command and Data loading):  
1. 1. A: Load Command “0100 0000”.  
2. 2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.  
3. 3. Set BS2, BS1 to “10”. This selects extended data byte.  
4. 4. Give WR a negative pulse and wait for RDY/BSY to go high.  
5. 5. Set BS2, BS1 to “00”. This selects low data byte.  
Figure 25-5. Programming the FUSES Waveforms  
Write Fuse Low byte  
Write Fuse high byte  
Write Extended Fuse byte  
A
C
A
C
A
C
0x40  
DATA  
XX  
0x40  
DATA  
XX  
0x40  
DATA  
XX  
DATA  
XA1  
XA0  
BS1  
BS2  
XTAL1  
WR  
RDY/BSY  
RESET +12V  
OE  
PAGEL  
25.7.11 Programming the Lock Bits  
The algorithm for programming the Lock bits is as follows (refer to “Programming the Flash” on  
page 253 for details on Command and Data loading):  
1. A: Load Command “0010 0000”.  
2. C: Load Data Low Byte. Bit n = “0” programs the Lock bit. If LB mode 3 is programmed  
(LB1 and LB2 is programmed), it is not possible to program the Boot Lock bits by any  
External Programming mode.  
3. Give WR a negative pulse and wait for RDY/BSY to go high.  
The Lock bits can only be cleared by executing Chip Erase.  