ATmega169P
J. End Page Programming
1. 1. Set XA1, XA0 to “10”. This enables command loading.
2. Set DATA to “0000 0000”. This is the command for No Operation.
3. Give XTAL1 a positive pulse. This loads the command, and the internal write signals are
reset.
Figure 26-2. Addressing the Flash Which is Organized in Pages(1)
PCMSB
PAGEMSB
PROGRAM
COUNTER
PCPAGE
PCWORD
PAGE ADDRESS
WITHIN THE FLASH
WORD ADDRESS
WITHIN A PAGE
PROGRAM MEMORY
PAGE
PAGE
INSTRUCTION WORD
PCWORD[PAGEMSB:0]:
00
01
02
PAGEEND
Note:
1. PCPAGE and PCWORD are listed in Table 26-6 on page 298.
Figure 26-3. Programming the Flash Waveforms(1)
F
A
B
C
D
E
B
C
D
E
G
H
0x10
ADDR. LOW
DATA LOW
DATA HIGH
ADDR. LOW DATA LOW
DATA HIGH
ADDR. HIGH
XX
XX
XX
DATA
XA1
XA0
BS1
XTAL1
WR
RDY/BSY
RESET +12V
OE
PAGEL
BS2
Note:
1. “XX” is don’t care. The letters refer to the programming description above.
303