 浏览型号AT90PWM3B-16SU的Datasheet PDF文件第344页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第345页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第346页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第347页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第349页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第350页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第351页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第352页  
32. Errata  
32.1 AT90PWM2&3 Rev. A (Mask Revision)  
PGM: PSCxRB Fuse  
PSC: Prescaler  
PSC: PAOCnA and PAOCnB Register Bits (Asynchronous output control)  
PSC: PEVxA/B Flag Bits  
PSC: Output Polarity in Centered Mode  
PSC: Output Activity  
VREF  
DALI  
DAC: Register Update  
DAC: Output spikes  
DAC driver: Output Voltage linearity  
ADC: Conversion accuracy  
Analog comparator: Offset value  
Analog comparator: Output signal  
PSC: Autolock modes  
DALI: 17th bit detection  
PSC: One ramp mode with PSC input mode 8  
1. PGM: PSCnRB Fuse  
The use of PSCnRB fuse can make the parallel ISP fail.  
Workaround:  
When PSCnRB fuses are used, use the serial programming mode to load a new program  
version.  
2. PSC: Prescaler  
The use of PSC's prescaler have the following effects :  
It blocks the sample of PSC inputs until the two first cycles following the set of PSC run bit.  
A fault is not properly transferred to other (slave) PSC.  
Workaround:  
Clear the prescaler PPREx bit when stopping the PSC (prun = 0), and set them to appropri-  
ate value when starting the PSC (prun = 1), these bits are in the same PCTL register  
Do not use the prescaler when a fault on one PSC should affect other PSC’s  
3. PSC: PAOCnA and PAOCnB Register Bits (Asynchronous output control)  
These register bits are malfunctioning.  
Workaround:  
Do not use this feature.  
4. PSC: PEVnA/B flag bits  
These flags are set when a fault arises, but can also be set again during the fault itself.  
Workaround:  
Don't clear these flags before the fault disappears.  
348  
AT90PWM2/3/2B/3B  
4317J–AVR–08/10  
 复制成功!