欢迎访问ic37.com |
会员登录 免费注册
发布采购

AT89S52-33AC 参数 Datasheet PDF下载

AT89S52-33AC图片预览
型号: AT89S52-33AC
PDF下载: 下载PDF文件 查看货源
内容描述: 8位微控制器具有8K字节的系统内可编程闪存 [8-bit Microcontroller with 8K Bytes In-System Programmable Flash]
分类和应用: 闪存微控制器和处理器外围集成电路异步传输模式ATM时钟
文件页数/大小: 30 页 / 231 K
品牌: ATMEL [ ATMEL ]
 浏览型号AT89S52-33AC的Datasheet PDF文件第9页浏览型号AT89S52-33AC的Datasheet PDF文件第10页浏览型号AT89S52-33AC的Datasheet PDF文件第11页浏览型号AT89S52-33AC的Datasheet PDF文件第12页浏览型号AT89S52-33AC的Datasheet PDF文件第14页浏览型号AT89S52-33AC的Datasheet PDF文件第15页浏览型号AT89S52-33AC的Datasheet PDF文件第16页浏览型号AT89S52-33AC的Datasheet PDF文件第17页  
AT89S52  
Baud Rate Generator  
Timer 2 is selected as the baud rate generator by setting  
TCLK and/or RCLK in T2CON (Table 2). Note that the  
baud rates for transmit and receive can be different if Timer  
2 is used for the receiver or transmitter and Timer 1 is used  
for the other function. Setting RCLK and/or TCLK puts  
Timer 2 into its baud rate generator mode, as shown in Fig-  
ure 8.  
increments every state time (at 1/2 the oscillator fre-  
quency). The baud rate formula is given below.  
Modes 1 and 3  
Oscillator Frequency  
--------------------------------------- = -------------------------------------------------------------------------------------  
Baud Rate 32 x [65536-RCAP2H,RCAP2L)]  
The baud rate generator mode is similar to the auto-reload  
mode, in that a rollover in TH2 causes the Timer 2 registers  
to be reloaded with the 16-bit value in registers RCAP2H  
and RCAP2L, which are preset by software.  
where (RCAP2H, RCAP2L) is the content of RCAP2H and  
RCAP2L taken as a 16-bit unsigned integer.  
Timer 2 as a baud rate generator is shown in Figure 8. This  
figure is valid only if RCLK or TCLK = 1 in T2CON. Note  
that a rollover in TH2 does not set TF2 and will not gener-  
ate an interrupt. Note too, that if EXEN2 is set, a 1-to-0  
transition in T2EX will set EXF2 but will not cause a reload  
from (RCAP2H, RCAP2L) to (TH2, TL2). Thus, when Timer  
2 is in use as a baud rate generator, T2EX can be used as  
an extra external interrupt.  
The baud rates in Modes 1 and 3 are determined by Timer  
2’s overflow rate according to the following equation.  
Timer 2 Overflow Rate  
Modes 1 and 3 Baud Rates = -----------------------------------------------------------  
16  
Note that when Timer 2 is running (TR2 = 1) as a timer in  
the baud rate generator mode, TH2 or TL2 should not be  
read from or written to. Under these conditions, the Timer is  
incremented every state time, and the results of a read or  
write may not be accurate. The RCAP2 registers may be  
read but should not be written to, because a write might  
overlap a reload and cause write and/or reload errors. The  
timer should be turned off (clear TR2) before accessing the  
Timer 2 or RCAP2 registers.  
The Timer can be configured for either timer or counter  
operation. In most applications, it is configured for timer  
operation (CP/T2 = 0). The timer operation is different for  
Timer 2 when it is used as a baud rate generator. Normally,  
as a timer, it increments every machine cycle (at 1/12 the  
oscillator frequency). As a baud rate generator, however, it  
Figure 9. Timer 2 in Clock-Out Mode  
TL2  
TH2  
÷2  
OSC  
(8-BITS) (8-BITS)  
TR2  
RCAP2L RCAP2H  
C/T2 BIT  
P1.0  
(T2)  
÷2  
T2OE (T2MOD.1)  
TRANSITION  
DETECTOR  
P1.1  
(T2EX)  
TIMER 2  
INTERRUPT  
EXF2  
EXEN2  
13  
 复制成功!