AT22V10/L
D.C. Characteristics
Symbol Parameter
Condition
Min
Typ
Max
Units
V
IN
V
= -0.1 V to V +1
CC
I
LI
Input Load Current
10
µA
Output Leakage
Current
I
LO
V
OUT
= -0.1 V to V +0.1 V
10
µA
CC
Com.
90
100
55
mA
mA
AT22V10-15,-20
Ind., Mil.
V
V
= MAX,
= GND,
CC
Power Supply
Current
(2)
I
CC
IN
AT22V10-25,-35
mA
Outputs Open
Com.
1.7
2.0
2.0
2.0
12
mA
(2)
AT22V10L
Ind., Mil.
Com.
15
mA
mA/MHz
mA/MHz
Clocked Power
Supply Current
V
= MAX,
CC
(2)
I
I
AT22V10L
CC2
Outputs Open
Ind., Mil.
Output Short
Circuit Current
(1)
V
OUT
= 0.5 V
-120
mA
OS
V
V
Input Low Voltage
Input High Voltage
-0.6
2.0
0.8
VCC+0.75
0.5
V
V
V
V
V
V
V
IL
IH
I
I
I
I
I
= 16 mA
= 12 mA
= 24 mA
= -100 µA
= -4.0 mA
Com.,Ind.
Mil.
OL
OL
OL
OH
OH
Output Low
Voltage
V
V
= V or V ,
IN
IH
IL
V
V
OL
0.5
= MIN
CC
Com.
0.8
VCC-0.3
2.4
Output High
Voltage
V =V or V ,
IN
IH
IL
OH
V
CC
=MIN
2. See ICC vs. Frequency curves in the back of this data sheet.
Notes: 1. Not more than one output at a time should be
shorted. Duration of short circuit test should not ex-
ceed 30 sec.
1-99