AT29C512
9. AC Read Characteristics
AT29C512-70
Symbol
t
ACC
t
CE(1)
t
OE(2)
t
DF(3)(4)
t
OH
Parameter
Address to Output Delay
CE to Output Delay
OE to Output Delay
CE or OE to Output Float
Output Hold from OE, CE or
Address, whichever
occurred first
0
0
0
Min
Max
70
70
35
10
0
0
0
AT29C512-90
Min
Max
90
90
40
25
0
0
0
AT29C512-12
Min
Max
120
120
50
30
0
0
0
AT29C512-15
Min
Max
150
150
70
40
Units
ns
ns
ns
ns
ns
Note:
Not recommended for New Designs.
10. AC Read Waveforms
Notes:
1. CE may be delayed up to t
ACC
- t
CE
after the address transition without impact on t
ACC
.
2. OE may be delayed up to t
CE
- t
OE
after the falling edge of CE without impact on t
CE
or by t
ACC
- t
OE
after an address change
without impact on t
ACC
.
3. t
DF
is specified from OE or CE whichever occurs first (CL = 5 pF).
4. This parameter is characterized and is not 100% tested.
7