60W Single Output Switching Power Supply
AQ-60 ꢀerieꢀ
ꢏꢃꢆꢍꢌꢄꢃꢅꢈꢔ
�ꢀꢁꢂꢃꢄꢅꢆꢇꢈꢉꢊꢈꢁꢀꢋꢌꢍꢈꢎꢈꢏꢌꢇꢇꢈꢄꢆꢀꢐꢃ
ꢑꢄꢒꢍꢃꢓꢍꢁꢒꢀꢅꢔꢕꢖꢒꢄꢍꢈꢓꢁꢄꢓꢌꢁꢍꢎꢗꢂꢃꢄꢈꢇꢒꢆꢘꢎꢗꢂꢃꢄꢈꢂꢒꢇꢍꢆꢐꢃ
ꢊꢒꢒꢇꢁꢀꢐꢈꢙꢚꢈꢛꢄꢃꢃꢈꢆꢁꢄꢈꢓꢒꢀꢂꢃꢓꢍꢁꢒꢀ
ꢜꢝꢞꢈꢁꢀꢘꢁꢓꢆꢍꢒꢄꢈꢛꢒꢄꢈꢋꢒꢟꢃꢄ ꢒꢀ
ꢏꢁꢠꢃꢘꢈꢅꢟꢁꢍꢓꢖꢁꢀꢐꢈꢛꢄꢃꢡꢌꢃꢀꢓꢚꢈꢆꢍꢈꢢꢣꢤꢥꢦ
ꢧꢈꢚꢃꢆꢄꢅꢈꢟꢆꢄꢄꢆꢀꢍꢚ
SPECIFICATION
AQ-60B
Q-60B
AQ-60C
Q-60C
AQ-60D
Q-60D
MODEL
DC�VOLTAGE
5V
12V
2A
-5V
-12V
5V
15V
-5V
-15V
5V
4A
12V
1A
24V
1A
-12V
0.5A
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
5.5A
0.5A
0.5A
5.5A
1.5A
0.5A
0.5A
0.5�~�8A 0.1�~�3A 0�~�1A
60W
0�~�1A
0.5�~�8A 0.1�~�3A 0�~�1A
60W
0�~�1A
0.5�~�8A 0.1�~�3A 0.1�~�1.5A 0�~�1A
62W
RIPPLE�&�NOISE�(max.) Note.2 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 150mVp-p 120mVp-p
VOLTAGE ADJ.�RANGE
VOLTAGE�TOLERANCE Note.3 2.0%
OUTPUT
CH1:�4.75�~�5.5V
CH1:�4.75�~�5.5V
CH1:�4.75�~�5.5V
6.0%
1.0%
4.0%
5.0%
0.5%
1.0%
5.0%
0.5%
1.0%
2.0%
0.5%
0.5%
+8,-4%
2.0%
5.0%
0.5%
1.0%
5.0%
0.5%
1.0%
2.0%
0.5%
0.5%
6.0%
1.0%
4.0%
+8,-4%
2.0%
5.0%
0.5%
1.0%
LINE�REGULATION
0.5%
0.5%
LOAD�REGULATION
SETUP,�RISE,�HOLD�TIME
4.0%
4.0%
800ms,�20ms,�60ms/230VAC����������1600ms,�20ms,�12ms/115VAC�at�full�load
VOLTAGE�RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC�CURRENT
85�~�264VAC����������120�~�370VDC
47�~�63Hz
70%
72%
75%
INPUT
2A/115VAC����������0.8A/230VAC
INRUSH�CURRENT�(max.)
COLD�START 18A/115VAC����������36A/230VAC
<1mA /�240VAC
LEAKAGE�CURRENT
105�~�150%/115VAC rated�output�power
OVER�LOAD
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
PROTECTION
ENVIRONMENT
5V:�5.75�~�6.75VDC
OVER�VOLTAGE
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
-10�~�+60 (Refer�to�output�load�derating�curve)
WORKING�TEMP.
20�~�90%�RH�non-condensing
-20�~�+85 ,�10�~�95%�RH
WORKING�HUMIDITY
STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
0.03%/ (0�~�50 )�on�+5V�output
VIBRATION
10�~�500Hz,�2G�10min./1cycle,�60min.�each�along�X, Y,�Z�axes
UL60950 Approved
SAFETY STANDARDS
WITHSTAND�VOLTAGE
I/P-O/P:3KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
ISOLATION�RESISTANCE
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
EMS�IMMUNITY
SAFETY &
I/P-O/P,�I/P-FG,�O/P-FG:100M�Ohms/500VDC
Compliance�to�EN55022�(CISPR22)�Class�B
EMC
(Note�4)
Compliance�to EN61000-3-2,-3
Compliance�to EN61000-4-2,3,4,5,6,8,11;�ENV50204,�Light�industry�level,��criteria A
MTBF
284.8K�hrs�min.������MIL-HDBK-217F�(25
159*97*38mm�(L*W*H)
)
DIMENSION
OTHERS
NOTE
0.56Kg;�24pcs/14.4Kg/0.75CUFT
PACKING
ꢨꢩꢈꢉꢇꢇꢈꢋꢆꢄꢆꢪꢃꢍꢃꢄꢅꢈꢫꢗꢬꢈꢅꢋꢃꢓꢁꢆꢇꢇꢚꢈꢪꢃꢀꢍꢁꢒꢀꢃꢘꢈꢆꢄꢃꢈꢪꢃꢆꢅꢌꢄꢃꢘꢈꢆꢍꢈꢧꢢꢭꢮꢉꢊꢈꢁꢀꢋꢌꢍꢯꢈꢄꢆꢍꢃꢘꢈꢇꢒꢆꢘꢈꢆꢀꢘꢈꢧꢣ ꢒꢛꢈꢆꢪꢙꢁꢃꢀꢍꢈꢍꢃꢪꢋꢃꢄꢆꢍꢌꢄꢃꢩ
ꢧꢩꢈꢰꢁꢋꢋꢇꢃꢈꢱꢈꢀꢒꢁꢅꢃꢈꢆꢄꢃꢈꢪꢃꢆꢅꢌꢄꢃꢘꢈꢆꢍꢈꢧꢭꢲꢥꢦꢈꢒꢛꢈꢙꢆꢀꢘꢟꢁꢘꢍꢖꢈꢙꢚꢈꢌꢅꢁꢀꢐꢈꢆꢈꢨꢧꢳꢈꢍꢟꢁꢅꢍꢃꢘꢈꢋꢆꢁꢄꢴꢟꢁꢄꢃꢈꢍꢃꢄꢪꢁꢀꢆꢍꢃꢘꢈꢟꢁꢍꢖꢈꢆꢈꢭꢩꢨꢌꢛꢈꢱꢈꢵꢶꢌꢛꢈꢋꢆꢄꢆꢇꢇꢃꢇꢈꢓꢆꢋꢆꢓꢁꢍꢒꢄꢩ
ꢢꢩꢈꢬꢒꢇꢃꢄꢆꢀꢓꢃꢈꢔꢈꢁꢀꢓꢇꢌꢘꢃꢅꢈꢅꢃꢍꢈꢌꢋꢈꢍꢒꢇꢃꢄꢆꢀꢓꢃꢯꢈꢇꢁꢀꢃꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢈꢆꢀꢘꢈꢇꢒꢆꢘꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢩ
ꢵꢩꢈꢬꢖꢃꢈꢋꢒꢟꢃꢄꢈꢅꢌꢋꢋꢇꢚꢈꢁꢅꢈꢓꢒꢀꢅꢁꢘꢃꢄꢃꢘꢈꢆꢈꢓꢒꢪꢋꢒꢀꢃꢀꢍꢈꢟꢖꢁꢓꢖꢈꢟꢁꢇꢇꢈꢙꢃꢈꢁꢀꢅꢍꢆꢇꢇꢃꢘꢈꢁꢀꢍꢒꢈꢆꢈꢛꢁꢀꢆꢇꢈꢃꢡꢌꢁꢋꢪꢃꢀꢍꢩꢈꢬꢖꢃꢈꢛꢁꢀꢆꢇꢈꢃꢡꢌꢁꢋꢪꢃꢀꢍꢈꢪꢌꢅꢍ ꢙꢃꢈꢄꢃꢴꢓꢒꢀꢛꢁꢄꢪꢃꢘꢈꢍꢖꢆꢍꢈꢁꢍꢈꢅꢍꢁꢇꢇꢈꢪꢃꢃꢍꢅ
ꢝꢲꢊꢈꢘꢁꢄꢃꢓꢍꢁꢂꢃꢅꢩ
300 Myleꢀ standiꢀh Blvd., Taunton, MA 02780
WWW.AsTRODYNE.COM
Ph: 1-800-823-8082
Fax: 508-823-8181